background image

F.   INSTALL STEM ADAPTER WITH 1/4” FEEDWATER  

 

TUBE OUTLET

 

IMPORTANT NOTES

•  For  basement  installations,  the  existing  orange  feed 

water tubing may have to be longer to reach the faucet 
adapter.

1)  Open faucet and turn off cold water supply to relieve pres-

sure. 

2)  Locate the cold water stem on the underside of the faucet 

fixture.  Unscrew  the  cold  water  feed  tube  from  the  faucet 
stem. Locate the Faucet Adapter that came with your drink-
ing water system. Insert the black gasket into the threaded 
adapter and tighten onto the Faucet Cold Water Stem under 
the sink, making sure that 1/4” side connection is accessible 
and not facing the wall. Make sure not to overtighten.

3)  Take the Cold Water Feed Tube and attach to the Faucet 

Adapter, making sure not to over tighten.

4)  Locate  the  1/4”  Orange  Tubing  and  insert  into  the  1/4” 

outlet of Faucet Adapter. See Figure 3 and “Using Push-in 
Fittings” below.

5)  Leave cold water supply off.

G.   INSTALLATION SANITIZING* 

 

PREFILL AND SANITIZE THE STORAGE TANK

To reduce the risk associated with eye, skin and respiratory and di-

gestive tract burns from Calcium Hypochlorite during installation:

• 

Calcium Hypochlorite (CAS 7778-54-3) granules are 

used for tank sanitation in this product.

• 

During installation, do not get in eyes, on skin or 

clothing. Do not ingest. Wear eye and face protection. 

Keep out of reach of children.

• 

To request an MSDS relating to this product, call 203-

238-8965 or visit the web at http://solutions.3m.com/

wps/portal/3M/en_US/MSDS (click MSDS search). For 

emergencies, call 800-364-3577 or 651-737-6501 (24 

hours).

To reduce the risk associated with ingestion of water contaminated 

with sanitizer:

• 

Sanitizer must be flushed from the system before 

using as directed within the installation instructions.

Prefilling the storage tank is always recommended so that there 
is pressure to check for leaks as well as sufficient water to flush 
the carbon postfilter.  The SQC RO Drinking Water Appliance 
is furnished with a container of special sanitizing granules. It is 
important to use a sanitizer when prefilling the tank.
1)  Remove protective cover from storage tank and discard.      
      Locate the enclosed container of sanitizing granules, open 
      it and pour the contents into the end of the tank. Apply PTFE 
      tape (not included) to threaded tank connection and install 
      tank valve onto connection. Do not over tighten. Open the 
      tank valve so that the tank valve handle is parallel to the 
      valve body. 
2)  Disconnect the 3/8” yellow tubing from the back of the 
 

filtration assembly and connect one end of it into the tube 

 

fitting located on the tank valve.

3)  Connect the other end of the 3/8” yellow tubing to the 3/8” 
 

x 1/4” union connector included in the tank sanitization kit.

4)  Connect the free end of the 1/4” orange feed water tubing 
 

to the other end of the 3/8” x 1/4” union connector.

5)  Open the cold water supply shut off valve (making sure the  
 

tank valve is still open) and allow the tank to fill (about  

 

3 minutes).

6)  Close the cold water supply shut off valve and the tank valve.  
 

Disconnect the 3/8” yellow tubing from the tank valve elbow 

 

fitting and set the tank aside while proceeding with the rest of 

 

the installation (the sanitizatizing solution should be kept in the 

 

tank for at least 15 minutes).

7)  Reconnect the 3/8” yellow tubing to the back of the 
 

filtration assembly.  Reconnect the 1/4” orange tubing to 

 

the feed water fitting on the filtration assembly.

IMPORTANT NOTES

•  If you encounter difficulty in removing the tubing from the 

tank, make sure the tank valve is closed and then cut the 
yellow tubing approximately 1” away from the tank valve 
fitting to relieve the pressure.  Remove the 1” piece from 
the tank fitting.

•  If an alternate storage tank is used, it should be sanitized 

with household bleach (5-1/4%).  Use 3 ml. (1/2 teaspoon) 
of bleach for a 2.5 gallon tank.

•  After the installation is complete, it is recommended that 

the 3/8” x 1/4” union connector be saved for future use in 
tank sanitization.

* For Yearly Owner Maintenance Sanitizing Instructions, see page 14

6

To Release Tubing

Push in grey collet to 

release tubing. With 

collet held, pull tubing 

straight out. 

Collet

Backstop

“Using Push-In Fittings”

To Attach Tubing

Push tubing in as 

far as it will go. 

Tubing must be 

inserted past o-ring

and hit backstop. 

Pull tube to ensure it is secured.

CAUTION

To reduce the risk associated with property damage due to 

water leakage:

  •  Ensure all tubing and fi ttings are secure and free of leaks.

Fig. 3

Orange Tubing

Faucet Stem

Undersink

Feedwater

Tube

Содержание SQC3 Series

Страница 1: ...ries Owner s Manual This Manual is for the Installation Operation and Maintenance of the WATER FACTORY SYSTEMS SQC3 and SQC4 Series Reverse Osmosis RO Drinking Water Appliance Installer Leave with hom...

Страница 2: ......

Страница 3: ...Number 070595 CT 001 An approved air gap must exist between the RO System reject drain line and the drain line opening to meet plumbing codes To reduce the risk associated with irritation from Sodium...

Страница 4: ...urs Do not install in direct sunlight or outdoors All hydro pneumatic tanks must have an appropriate pressure relief valve installed Do not install near water pipes which will be in path of a drilling...

Страница 5: ...mber Failure to install the system as instructed will VOID the warranty TABLE OF CONTENTS I Installation Instructions A Determine the appliance location 3 B Prepare the area for installation 3 C Prepa...

Страница 6: ...s fittings and tubing that may be required B PREPARE THE AREA FOR INSTALLATION Re move supplies from under the sink and stack them neatly away from the working area Ar range a light for the work area...

Страница 7: ...e faucet such as reinforcing ribs support brackets or the cabinet construction Stainless steel sink air gap or non air gap faucet Recommended tools Center punch Variable speed drill and high speed dri...

Страница 8: ...ir gap tubing and the threaded nipple through the faucet mounting hole and position the faucet spout over the sink 6 From below the sink countertop install the white spacer open side toward the air ga...

Страница 9: ...ntainer of sanitizing granules open it and pour the contents into the end of the tank Apply PTFE tape not included to threaded tank connection and install tank valve onto connection Do not over tighte...

Страница 10: ...h side Do not overtighten See Fig 5 5 Orient the elbow in the direction of the RO faucet location I INSTALL THE FILTRATION ASSEMBLY AND STORAGE TANK For Basement Installation See Installation Instruct...

Страница 11: ...dispenser It should never be connected to a commercial type bar icemaker Hooking up an icemaker involves connecting a tee with a shut off valve into the 3 8 blue faucet tubing and routing the tubing...

Страница 12: ...the reject flow by disconnecting the tubing at the drain connection and measuring the drip rate as outlined above The ratio should be a minimum of 2 5 reject to 1 product Repeat every 5 minutes until...

Страница 13: ...k 1 4 green tubing Air Gap Device e g Gap A Flow Laundry Sink Standpipe or Floor Drain Basement Floor Storage Tank Valve Red SFC Tubing Filtration assembly For best flow keep the tubing as short as po...

Страница 14: ...ts To mount the filtration assembly keep the bracket level and mark the location of the mounting holes Install wall anchors and or mount ing screws as required Leave the screw heads protruding to allo...

Страница 15: ...Close the icemaker valve and wait until the faucet drips Wait for the air to be purged from the system Problem Water leaks from air gap module opening Possible Causes The drain line tubing is looped...

Страница 16: ...move cover and twist the filter cartridge 1 4 turn clockwise so that the ears on the cartridge are able to disengage from the head Firmly pull the cartridge from the head It may be necessary to twist...

Страница 17: ...mbrane cartridge as far as it will go Line up the cartridge ears insert the cartridge and push it into the head until it is fully seated Twist the cartridge 1 4 turn counterclockwise to lock it into p...

Страница 18: ...e filtration assembly to depressurize 2 Remove all of the filter cartridges Turn the cartridges upside down in the sink to drain out as much water from them as possible 3 Place the cartridges in an ai...

Страница 19: ......

Страница 20: ...If the Product fails to satisfy this Limited Warranty during the warranty period 3M will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated...

Отзывы: