Step 1S 

– Press NEXT and 

 

simultaneously for 3 seconds and release. If screen in Step 2S does 

not  appear in 5 seconds the lock on the valve is activated. To unlock press 

, NEXT, 

, and 

CLOCK in sequence, then press NEXT and 

 

simultaneously for 3 seconds and release. 

 
 
Step 2S 

–  Choose SOFTENING using the 

 

or 

 

button. Press NEXT to go to Step 3S. Press 

REGEN to exit Softener System Setup. 

 
 
 
 
 
Step 3S 

– Select the time for the first cycle (which in this example is BACKWASH) using the 

 

or 

 

button. Press NEXT to go to Step 4S. Press REGEN to return to previous step. 

 
 
 

 
Step 4S 

– Select the time for the second cycle (which in this example is dn BRINE) using the 

 

or 

 

button. Press NEXT to go to Step 5S. Press REGEN to return to previous step. 

NOTE: The display will . ash between cycle number and time, and brine direction (dn or UP). 

 
 

 
Step 5S 

– Select the time for the third cycle (which in this example is RINSE) using the 

 

or 

 

button. Press NEXT to go to Step 6S. Press REGEN to return to previous step. 

 
 
 

 
Step 6S 

–  Select the  LBS for the fourth cycle (which in this example is FILL) using the 

 

or 

 

button. Press NEXT to go to Step 7S. Press REGEN to return to previous step. 

 

 
Step 7S 

–Set Grains Capacity using the 

 

or 

 

button. The ion exchange capacity is in grains of 

hardness as calcium carbonate for the system based on the pounds of salt that will be used. 
Calculate  the pounds of salt using the fill time previously selected. The allowable grains capacity 
range varies from 5000 to 500,000 grains. The increment increase is 500 for the range from 5000 to 
50,000; 2000  for the range of 50,000 to 200,000; and 5000 for the range of 200,000 to 500,000. 
Grains capacity is  affected by the fill time. The grains capacity for the selected fill time should be 
confirmed by testing. The capacity and hardness levels entered are used to automatically calculate 
reserve capacity when gallon capacity is set to AUTO. Press NEXT to go to Step 8S. Press REGEN 
to return to previous step.

 

 

 

Step 8S 

– Set Volume Capacity using the

or 

 

button. If value is set to: 

• “AUTO” capacity will be automatically calculated and reserve capacity will be automatically estimated; 
• “oFF” regeneration will be based solely on the day override set (see Installer Display Settings Step 3I); or 
• as a number (allowable range 20 to 250,000) regeneration initiation will be based off the value specified. 
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000, 500 for the range 10,000 to 
50,000 and 2000 for the range of 50,000 to 250,000. 
If “oFF” or a number is used, hardness display will not be allowed to be set in Installer Display Settings Step 2I. 
See Table 8 for more detail. Press NEXT to go to Step 9S. Press REGEN to return to previous step. 

STEP 9S

 

Step 9S 

– Set Regeneration Time Options using the 

 

or 

 

button. If value is set to: 

• “NORMAL” means regeneration will occur at the preset time; 
• “on 0” means regeneration will occur immediately when the gallons capacity reaches 0 (zero); or 
• “ on 0” means regeneration will occur at one of the following: 

— the preset time when the gallons capacity falls below the reserve or the specified number of days between  

regenerations is reached, whichever comes first; or 

— after 10 minutes of no water usage when the gallon capacity reaches 0 (zero). 

See Table 8 for more detail. Press NEXT to go to Step 10S. Press REGEN to return to previous step. 

 

Page 7 

Содержание PLATINUM SERIES

Страница 1: ...TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENT...

Страница 2: ...ngs 4 Installer Display Settings 6 Softener System Setup 6 Softener Setting Options 8 Diagnostics 9 Troubleshooting 10 Installation 12 Bypass Valve 14 Specifications 15 Quick Reference Specifications...

Страница 3: ...o ring seals After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack f...

Страница 4: ...days left before the system goes through a regeneration cycle Capacity remaining is the gallons that will be treated before the system goes through a regeneration cycle Pressing the button while in t...

Страница 5: ...on 0 press and release REGEN The words REGEN TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in err...

Страница 6: ...capacity is set to AUTO or to a number sets the maximum number of days between regenerations If value set to oFF regeneration initiation is based solely on volume used If value is set as a number all...

Страница 7: ...00 for the range of 200 000 to 500 000 Grains capacity is affected by the fill time The grains capacity for the selected fill time should be confirmed by testing The capacity and hardness levels enter...

Страница 8: ...acity reaches 0 Any number On O oFF Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of regeneration will not be allowed to be set beca...

Страница 9: ...Press the NEXT button at any time to go to Step 5D Press REGEN to return to previous step STEP 1D Press and simultaneously for three seconds If screen in step 2D does not appear in 5 seconds the lock...

Страница 10: ...on 0 e Check control valve set up procedure regeneration time option 5 ERROR followed by code number Error code 1001 Unable to recognize start of regeneration Error Code 1002 Unexpected stall Error C...

Страница 11: ...or drive cap assembly d Defective PC board d Replace PC board 8 Control valve does not regenerate automatically but does when REGEN button is depressed a By pass valve in bypass position a Put bypass...

Страница 12: ...use an elbow fitting that does not contain a hole If the drain line is a 5 8 flexible polytube slide the nut onto the polytube then place the polytube insert into the end of the polytube and tighten...

Страница 13: ...t onto the fitting first then the split ring second and the o ring last Hand tighten the nut If the fitting is leaking tightening the nut will not stop the leak Remove the nut remove the fitting and c...

Страница 14: ...The plug valves enable the bypass valve to operate in four positions 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the co...

Страница 15: ...m 113 5 lpm 25 psig 172 kPa drop Minimum Maximum Operating Pressures 20 psi 138 kPa 125 psi 862 kPa Minimum Maximum Operating Temperatures 40 F 4 C 110 F 43 C AC Adapter Supply Voltage Supply Frequenc...

Отзывы: