28
Trouble Shooting
Problem
Follow up
Action
Sulphur coming through
Check the amount of sulphur you
are trying to remove…it may be
too much to remove or low PH
Set to everyday regeneration, 60 min
draw
Iron coming through
Same as above, ph of 6.8 or lower
may require a ph filter
Same as above
Unit regenerating in
afternoon
Settings are incorrect
Go to unit set for 2 am setting
Not removing sulphur or
iron
Listen to back wash
1) Check for obstruction in
backwash, Check flow
restrictor, Regenerate more
often
2) Check the ozone generator
is working
3) Clean the ozone tube
Overview
Most service should be around the following:
1) Ozone is working
2) Brine draw is working…sucking
3) Board is set right
4) Increase the ozone draw, backwash etc.
5) Check chemistry of water
6) PH should be 6.8 or higher
7) Obstruction in drain line
8) Did not install the back flow check valve
9) Setting for ozone to come properly programmed
10) By Pass is not open
11) Too much iron or sulphur for unit
Error board flashing see manual for setting.
Содержание Blaster Soft
Страница 6: ...6...
Страница 11: ...11...
Страница 12: ...12...
Страница 13: ...13 Example Brine Line Installation...
Страница 15: ...15...
Страница 16: ...16 Platinum Drawings and Part Numbers...
Страница 29: ...29...
Страница 30: ...30...
Страница 31: ...31...
Страница 32: ...32...