background image

7314971 (Rev. U  2/2/21)

In

st

al

la

tio

an

O

pe

ra

tio

M

an

ua

l

Manufactured and warranted by

Water Channel Partners

1890 Woodlane Drive

Woodbury, MN 55125

How to install, operate 

and maintain your 

Reverse Osmosis 

Drinking Water System

Model ECOP30

System tested and certified by NSF International

against NSF/ANSI Standards 42 & 58.  See 

performance data on pages 27 & 28 for details.

If you have any questions or concerns when

installing, operating or maintaining your reverse

osmosis system, call our toll free number:

1-800-693-1138

or visit 

www.ecopure.com

When you call, please be prepared to provide

the model, date code and serial number of your

product, found on the rating decal, located

inside the cover.

PRODUCT REGISTRATION

AND WARRANTY EXTENSION

Please register your product on

www.ecopure.com
See warranty page for 

extended warranty details.

Содержание EcoPure ECOP30

Страница 1: ...2 58 See performance data on pages 27 28 for details If you have any questions or concerns when installing operating or maintaining your reverse osmosis system call our toll free number 1 800 693 1138...

Страница 2: ...ing 8 Step B Install Reverse Osmosis Drain 9 10 Step C Install Reverse Osmosis Filter Assembly 11 Step D Install Storage Tank 11 Step E Install Reverse Osmosis Faucet 12 13 Step F Connect Tubes 14 15...

Страница 3: ...er the system This system is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts Arsenic Reduction This system shall only be used for arsenic reduction...

Страница 4: ...r Reverse Osmosis Drinking Water System is shipped complete in one carton Remove all items from your shipping carton Check all items against the packing list below Note any items lost or damaged in sh...

Страница 5: ...point is needed for drain water from the Reverse Osmosis system REMOTE INTERIOR LOCATION The Reverse Osmosis Filter Assembly and storage tank may also be installed in a remote interior location away...

Страница 6: ...sis Drain Soft water to Reverse Osmosis System Hard Water to House Main Shutoff Valve Storage Tank Water Meter Reverse Osmosis System To Faucet Floor Drain Air Gap see p 11 Typical Under Sink Installa...

Страница 7: ...d filter assembly into planned location Check position of items and space required for proper installation Ensure tubes may be routed without kinking 3 Remove tank and filter from planned location and...

Страница 8: ...st provide a leak tight connection to the Reverse Osmosis 1 4 tubing Locate the cold water line in the sink cabinet It is recommended but not required that the cold water line be soft water Complete t...

Страница 9: ...trap See Fig 9 Make sure that the Q C fitting is toward the direction of the RO faucet See Fig 10 NOTE Locate so that the drain tubing from the Reverse Osmosis faucet will run straight to the adaptor...

Страница 10: ...e with an adequate length of tubing to reach the drain point Refer to Step F later in the manual on how to disconnect and connect tubing NOTE A flow control insert is located inside the elbow fitting...

Страница 11: ...ur later in the assembly 4 Place the storage tank next to the Reverse Osmosis Assembly The tank can be placed upright or on its side INSTALL REVERSE OSMOSIS FILTER ASSEMBLY The Reverse Osmosis Filter...

Страница 12: ...s adequate tube routing space between the faucet and filter assembly 4 If drilling is needed drill a 1 1 4 diameter hole in the mounting surface IMPORTANT Drilling holes into countertops and sinks sho...

Страница 13: ...faucet barb fitting on faucet See Figs 17 20 21 D Pull on the tubing to be sure it is held firmly in the fit ting 6 Mount the faucet body onto the faucet base 1 4 turn FAUCET ELECTRONICS Inside the fa...

Страница 14: ...collet until it engages the o ring See Fig 20 Continue pushing until the tube bottoms out against the back of the fitting See Fig 21 Do not stop pushing when the tube engages the o ring Failure to fo...

Страница 15: ...way into the fitting See Figs 20 21 5 Pull on the tube to be sure it s held firmly in the fitting CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1 Locate the 3 8 black tube attached...

Страница 16: ...e Figs 14 and 25 6 Sanitizing the system will be completed during the pressure test and purging steps on the following page NOTE The bleach must be removed from the system before drinking the water Se...

Страница 17: ...and do not per mit the use of saddle valves If you live in the state of Massachusetts review plumbing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installa tion PURGING...

Страница 18: ...stfilter before going to the Reverse Osmosis faucet See Fig 27 The postfilter is an activated carbon type filter Any remaining tastes and odors are reduced from the product water Clean high quality dr...

Страница 19: ...to the storage tank 5 Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain 6 Faucet is activated 7 Processed water leaves the storage tank and flows to the post...

Страница 20: ...the cartridge membrane and causes pin hole leaks It s time to replace the Reverse Osmosis cartridge when the pro duction rate and or quality of product water drops Product water may begin to taste di...

Страница 21: ...and insert the o ring seal into the bottom of the port See Figs 30 31 3 Push the collet inward until it locks in place See Figs 30 31 ChANGE BATTERY To change battery complete the following steps 1 Re...

Страница 22: ...ilter or Reverse Osmosis membrane cartridges plugged with sediment Correction Replace the prefilter cartridge If rate does not increase replace the postfilter cartridge and Reverse Osmosis membrane ca...

Страница 23: ...ee pages 14 15 Cause Tubing nicked Correction Remove tube from connection Remove nicked portion by cutting tube to shorter length Reinsert in connection See pages 14 15 If removing the drain line leav...

Страница 24: ...24 Exploded View 22 21 18 17 16 15 14 13 11 1 2 3 4 8 9 7 5 6 1 4 red tubing 12 10 8 20 23 19...

Страница 25: ...utomatic Shutoff Kit incl Key No 7 4 of Key No 6 6 of Key No 5 5 Screw 6 req d 6 Washer 4 req d 7 Automatic Shutoff Cover Assembly 7333179 Diaphragm Kit includes Key Nos 9 10 2 of Key No 8 8 Diaphragm...

Страница 26: ...xcept normal shipping and installation charges Labor to maintain the equipment is not part of the warranty Filters and membranes are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1...

Страница 27: ...ur water supply See elsewhere in this owner s manual for further instructions on filter replacement system installation operating procedures and warranty The maintenance instructions must be followed...

Страница 28: ...340 40 88 Sulfate7 800 10 2508 780 12 98 Tannin7 3 0 10 1 08 2 9 0 1 97 Zinc7 15 10 5 08 15 0 25 98 1 Milligrams per liter which is equivalent to parts per million PPM 2 Tested by NSF International ac...

Страница 29: ...ne minute any trivalent arsenic will be converted to pentavalent arsenic and reduced by this RO Other water treat ment chemicals such as ozone and potassium permanganate will also change trivalent ars...

Отзывы: