Water Care Ion Pro Series Скачать руководство пользователя страница 11

11

 OPERATING DISPLAYS AND MAINTENANCE:

The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; however, unlike these 
conventional filters, they use air as a regenerant. This atmospheric air (containing oxygen) helps convert iron or hydrogen 
sulfide into particles. These filters capture the particles of iron or hydrogen sulfide gas within the filter media. Your dealer has 
recommended the proper media depending on your local water conditions. In some cases where an acidic water condition 
(low pH) is present, the media may need to be periodically replenished if using this filter to raise the pH to an acceptable level. 
Consult dealer for this service. The system is prefactory set to regenerate every (3) three days at midnight. The frequency and 
start time of backwash/regeneration is adjustable to meet local operating conditions and contaminant levels. Total backwash 
and recharge time is normally one half hour.

     

1.  

GENERAL OPERATION:

 

When the system is operating, one of five displays may be shown and will alternate with the installing 

dealer’s name and phone number for future service. Pressing 

NEXT

 will alternate between the displays. 

 1. 

 CURRENT TIME OF DAY

 and 

GPM

 2. 

 FLOW RATE

 which is the current treated water flow rate through the system in Gallons Per Minute

 3. 

 VACATION MODE 

allows the system to be “shut down” when there will be no water usage for an extended period 

of time

 

4.  CAPACITY REMAINING

 which is the gallons that will be treated before the system signals a regeneration cycle

 5. 

 DAYS TO A REGEN

 is the number of days left before the system goes through a regeneration cycle, based on the days 

override value

 6. 

 DEALER NAME AND PHONE NUMBER

 is the dealer information to call when service is needed (this screen will only 

appear if set by dealer)

 

The user can scroll between the displays as desired.

     If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN 

TODAY” will appear on the display.

     If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per 

minute going through the system.

2. 

 VACATION MODE:

 

This feature may be used to “shut down” the system while on vacation. The manufacturer has 

factory set “OFF” as the default. Turn feature “OFF” or “ON” using the 

+

 or 

 buttons. When turned “ON”, the 

unit will not regenerate while there is no water usage. Once water usage is observed (minimum of 50 gallons), the 
unit will automatically regenerate that night and resume normal operation.

CAUTION:

  Depending on the severity of water conditions and the length of no water 

usage, it may not be recommended to use this feature. Please contact 
dealer or manufacturer for more information.

3.  

REGENERATION MODE:

 

Typically a system is set to regenerate at a time of no 

water usage. If there is a demand for water when the system is regenerating, untreated 
water will be delivered. When the system begins to regenerate, the display will include 
information about the step of the regeneration process and the time remaining for that 
step to be completed. The system runs through the steps automatically and will reset 
itself to provide treated water when the regeneration has been completed.

REGENERATION MODE

1

TIME OF DAY

MON

GPM

2:40

8

PM

2

FLOW RATE

GPM

8.0

5

ON VACATION

NO

6

PHONE NUMBER

DEALER NA

3

CAPACITY REMAINING

GPM

GAL

1600

8

4

DAYS TO A REGEN

GPM

3

8

Содержание Ion Pro Series

Страница 1: ...Ion Pro and CareClear Pro Series Water Filters For Models IPHS IPFE IPG IPCG AN CCP CCP AN...

Страница 2: ...ty 30 Quick Reference Guide 31 32 Your WaterCare water filters are precision built high quality products These units will deliver filtered water for many years to come when installed and operated prop...

Страница 3: ...y Remaining and Days to a Regeneration are optional displays but are not normally used Vacation Mode is used only when there will be no water usage for an extended period of time If activated once 50...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...een its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on the outlet side of the...

Страница 6: ...low control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but because of...

Страница 7: ...regeneration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use...

Страница 8: ...neration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 3 is recommended set number of days...

Страница 9: ...t OFF as the default This feature is used to signal service into the future This is typically set by the installing dealer to warn homeowner that service is required after a preset number of gallons h...

Страница 10: ...ushing and holding the REGEN button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The sys...

Страница 11: ...system goes through a regeneration cycle based on the days override value 6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed this screen will only appear if set by...

Страница 12: ...ed with an audible alarm and visual alarm This alarm is set by the installing dealer and is used to warn of pending service based on gallons or time To turn off alarm If the audible alarm sounds press...

Страница 13: ...o media level when filling Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the right height has been...

Страница 14: ...board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed...

Страница 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Страница 16: ...r 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap...

Страница 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Страница 18: ...iston position or disconnect power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detec...

Страница 19: ...buttons 1 CV3837 01 CareClear Pro cover blue buttons 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV4062WX PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV30...

Страница 20: ...w 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 CV3358 O ring 219 1 25 distributor 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 003183...

Страница 21: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...

Страница 22: ...0 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN not shown CV3170 O ring 011 lower not shown CV317...

Страница 23: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Страница 24: ...1 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the...

Страница 25: ...LY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH4640 32 474 float assembly 1 3 CH4500 48 474 air check 1 4 CN1043 10 pad for feeder 1 5 CH7001 Grid for feeder 1 REPLACEMENT...

Страница 26: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Страница 27: ...Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assem...

Страница 28: ...19 0 22 0 Continuous Flow GPM 3 0 3 0 5 0 3 0 3 0 5 0 2 Peak Flow GPM 6 0 8 0 10 0 6 0 8 0 10 0 Backwash Flow GPM 6 5 9 0 11 0 6 5 9 0 11 0 3 Iron Removal 4 0 4 0 4 0 4 0 4 0 4 0 4 Hydrogen Sulfide Re...

Страница 29: ...1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 5 0 5 0 6 0 6 0 7 0 11 0 Peak Flo...

Страница 30: ...xpense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition...

Страница 31: ...N TIME MINUTES SET TIME HOUR SET 2 00 AM MANUAL REGENERATION NOTE For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regeneration If you need to initia...

Страница 32: ...d button simultaneously 2 Adjust hardness using and buttons 3 Press NEXT 4 Adjust days between regenerations using and buttons 5 Press NEXT 6 Adjust time of regeneration hour with and buttons AM PM to...

Отзывы: