WAT-910BD H/W MANUAL
Please do not change the bit or the byte data with the notation of "-" among following tables.
(Camera operation will not be guaranteed.)
The default value can be found in
red underlined
(or, with notation of default) in the table.
0x09:OFF(E:1/60,C:1/50), 0x0A:FL, 0x0B:1/250,
*1:When switching to EI(Electronic Iris mode), it is recommended be used "FIX SHUTTER SPEED" parameter.
6.4 CAMERA PARAMETER
-
-
-
actual AGC MID MAX(dB) = ( [0x05 … 0xFF] * 4 * 0.035 ) + 5.3 (default:
0xD0
, approx.34.5(dB))
1:ON
0x10:1/10000, 0x11:1/100000
4
3
2
1
5
-
-
-
-
0:OFF
0
Bit
-
-
-
-
-
EI
(*1)
Address
0x400
-
-
7
6
-
-
-
0x403
-
-
-
-
0x405
-
-
-
-
-
-
-
0x407
-
-
-
-
-
-
-
-
-
-
0x409
-
-
-
-
-
-
0x408
-
-
-
0x40B
-
-
-
-
-
-
-
-
-
0x40A
-
-
-
-
-
-
0x40D
-
-
-
-
-
-
0x40C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0x40E
-
-
-
0x40F
-
-
-
-
FIX SHUTTER SPEED
0x00:x256, 0x01:x128, 0x02:x64, 0x03:x32, 0x04:x16,
0x05:x8, 0x06:x4, 0x07:x2,
0x08:EI
,
0x0C:1/500, 0x0D:1/1000, 0x0E:1/2000, 0x0F:1/5000,
-
-
-
-
-
0x410
-
-
-
-
(notice 2) Be sure to set large value than AGC MIN.
(notice 1) Be sure to set 5 or more large values.
-
-
-
-
actual AGC LOW MAX(dB) = ( [0x05 … 0xFF] * 4 * 0.035 ) + 5.3 (default:
0xB0
, approx.30(dB))
(notice 1) Be sure to set 5 or more large values.
(notice 2) Be sure to set large value than AGC MIN.
0x402
-
-
-
-
-
0x404
-
AGC MODE
0x401
-
-
-
-
0x00:OFF
0x01:LOW
0x02:MID
0x03:HI
-
actual AGC HI MAX(dB) = ( [0x05 … 0xFF] * 4 * 0.035 ) + 5.3 (default:
0xFF
, approx.41(dB))
(notice 1) Be sure to set 5 or more large values.
-
0x413
AGC LOW MAX
0x412
AGC MID MAX
-
-
0x411
AGC HI MAX
1:ON
SENS UP MAX
0x00:x2, 0x01:x4,
0x02:x8
,
0x06:x128, 0x07:x256(FLD)
0x03:x16, 0x04:x32, 0x05:x64,
FUNCTION
0x406
-
-
-
-
SENS UP
0:OFF
(notice 2) Be sure to set large value than AGC MIN.
- 35 -