Monochrome CCD Camera
Operation Manual
This Operation Manual covers safety, camera functions, installation and
the correct operating procedure for the WAT-902H
2/3
SUPREME. First,
we ask you to read this Operation Manual thoroughly, then install and
operate the WAT-902H
2/3
SUPREME as advised. In addition, for future
reference, we also advise safekeeping of this manual.
Please contact the distributor or dealer from which the WAT-
902H
2/3
SUPREME was purchased, if you do not understand the
installation, operation or safety instructions laid out in this manual. Not
understanding the contents of the Operation Manual sufficiently may
cause damage to the camera.
Guide to the Safety Symbols
The definitions of the symbols used in this operation manual are:
When you do not adhere to or take notice of the “Danger”
sign, it may lead to a serious accident such as death or
injury caused by fire or electric shock.
When you do not adhere to or take notice of the “Warning”
sign, it may cause severe damage such as a physical injury.
When you do not adhere to or take notice of the “Caution”
sign, it may incur injury and cause damage to peripheral
objects in the immediate surroundings.
Cautions for Safety
WAT-902H
2/3
SUPREME is designed to be used safely; however, if not
used safely, it may lead to a physical accident caused by fire and
electric shock. Therefore, please keep and read the “Cautions for
Safety” below for protection against accidents.
•
Do not disassemble and/or modify the WAT-902H
2/3
SUPREME.
•
Do not operate the WAT-902H
2/3
SUPREME with wet
i
hands.
•
Use a stabilized power adaptor designed for DC+12V
±
±
±
±
10%, with a current capacity of more than 250mA for
the WAT-902H2/3 SUPREME.
The recommended voltage is DC+12V
±
10%
•
Do not expose the WAT-902H
2/3
SUPREME to wetness
or high moisture conditions.
The WAT-902H
2/3
SUPREME is designed and approved
for indoor use only. The WAT-902H
2/3
SUPREME is not
water-resistant or waterproof. If the location of the camera
is outdoors or in an outdoor like environment, we
recommend that you use an outdoor camera housing.
•
Protect the WAT-902H
2/3
SUPREME from
condensation.
Keep the WAT-902H
2/3
SUPREME dry at all times during
storage and operation.
•
Should the camera not work properly, switch off the power
immediately. Then check the camera according to the
“Problems and Trouble Shooting” section.
•
Avoid the striking of hard objects or dropping the WAT-
902H
2/3
SUPREME.
The WAT-902H
2/3
SUPREME uses high quality electrical
parts and precision components.
•
i
Do not connect any power supply directly to the video
out terminal of the unit.
Do not connect the WAT-902H
2/3
SUPREME with any
monitor using a video/power single transmission terminal.
The WAT-902H
2/3
SUPREME is not designed for use with
this type of equipment. We also advise you to read the
operation manual of the monitor you plan to use before any
connections are made.
•
Do not install the WAT-902H
2/3
SUPREME in a position
subject to direct sunlight.
Sunlight shinning directly onto the WAT-902H
2/3
S
UPREME lens can cause damage to the CCD.
•
Select a stable place for installation of the WAT-
902H
2/3
SUPREME.
Use a support of durable strength around an installation
position on a ceiling or wall when a camera stand or tripod
is used.
•
Do not move the WAT-902H
2/3
SUPREME with the
cables connected.
Before moving the WAT-902H
2/3
SUPREME, always
remove the video cable and power cable from the rear of
the camera first.
•
Avoid using the WAT-902H
2/3
SUPREME near any
strong electromagnetic field.
After installing into main equipment, if the WAT-902H
2/3
SUPREME is exposed to electromagnetic waves causing
the monitored image to become distorted, we recommend
the camera be shielded by appropriate protective casing.
Problems and Trouble Shooting
If any of the following problems occur when using the WAT-
902H
2/3
SUPREME,
•
An optimal picture cannot be obtained, after checking that all the
cables and connections are correctly in place
•
Smoke or any unusual odor emerges from the WAT-902H
2/3
SUPREME
•
An object becomes embedded or a quantity of liquid seeps into the
camera housing
•
More than the recommended voltage or/and amperage has been
applied to the WAT-902H
2/3
SUPREME by mistake
•
Anything unusual occurring to any equipment connected to the
WAT-902H
2/3
SUPREME.
Disconnect the camera immediately according to the following procedures:
①
Switch off the main power supply to the camera.
②
Remove the power and video cables connected to the WAT-902H
2/3
SUPREME.
③
Contact the distributor or dealer from which the WAT-902H
2/3
SUPREME was purchased.
About EMC
The WAT-902H
2/3
SUPREME is in conformity with EMC test standards
carried out by authorized organizations in Japan.
E
I
A
/
FCC Part15 class B
CCIR EN61000-6-3/EN50130-4
Do not modify the WAT-902H
2/3
SUPREME. A modified
camera may not conform to EMC test standards.
Contents
Using the contents figures below, check to make sure all parts are
present before use.
Lens Mount Cap
WAT-902H
2/3
SUPREME
DC plug
Iris Connector
Description of Parts
①
CCD FRONT FACE
・
The light receiving face of the CCD camera
(Dirt, water or oil deposits on the CCD will cause an unclear picture on
the monitor. Attach the lens cap to protect the lens and CCD from
contamination and damage.)
②
LENS MOUNT
・
Mount for the lens (Thread type)
③
IRIS LEVEL VOLUME
・
By controlling the volume, the iris level of a DC iris lens can be
adjusted.
④
FOCUSING ADJUSTMENT SCREWS
・
There are 3 hex. adjustment screws each placed at intervals of 120
゜
for fine focusing of the lens.
⑤
AUTO-IRIS SOCKET
・
This socket is for a video or DC auto-iris lens cable connector.
(Video/DC: Auto selected by the camera)
⑥
TRIPOD MOUNTING SCREW HOLES
・
Mounting holes for stands. The size of these threads are 1/4”, 20
threads, 4.5
±
0.2mm, which is the same as any standard camera
tripod (U1/4”).
⑦
AE MODE CONTROL
・
The switch for the shutter speed mode control according to the object
being monitored
⑧
VIDEO OUT (BNC)
・
The terminal for composite video signal output
⑨
POWER IN
・
The terminal designed for connection with the DC-plug of the power
adaptor
⑩
AGC SELECTION SWITCH
・
Switch for setting AGC HI or LO
Power Supply
Use a stabilized power adaptor designed for DC+12V
±
10%, with a
current capacity of more than 250mA.
Use the optional DC plug if the shape or polarity of the DC plug of the
power adaptor to be used is not compatible with the camera (See the
drawing on the right below).
The wiring on the connector must be exact.
Be careful not to touch the other terminal while
wiring. Protect the wiring portion by using
insulation tape after wiring. If the above care and
attention is not adhered to, damage to the
WAT-902H
2/3
SUPREME
and power adaptor may
occur and may also cause fire.
Auto-iris Lens
Before connecting the auto-iris lens, please make sure that the pin
configuration is correct by confirming with the following table. If the
configuration of your iris connector is different from the following, the
plug and pins will need to be rewired.
Pin No.
EIAJ Video
Auto-iris Lens
Arrangement
EIAJ DC
Auto-iris Lens
Arrangement
①
Power
Control
-
②
Not used
Control
+
③
Iris signals
Drive
+
④
Common (GND)
Drive
-
Set-up and Operation
1) Ensure that the power to the WAT-902H
2/3
SUPREME and the
peripheral equipment is turned off before making any connections.
2) Remove the lens mount cap from the WAT-902H
2/3
SUPREME and
attach the CS-mount lens. Use the optional C-mount adaptor
(30CMA-R) when a C-mount lens is used.
3) Connect the iris control cable to
⑤
AUTO-IRIS SOCKET on the
WAT-902H
2/3
SUPREME when an auto-iris lens is being used.
4) Connect
⑧
VIDEO OUT on the WAT-902H
2/3
SUPREME with the
monitor, using a coaxial cable with 75
Ω
impedance, such as an
RG-58/U or an RG-6/U. Select a monitor with the same television
system as the WAT-902H
2/3
SUPREME: EIA or CCIR. A monitor with
more than 600TV lines is recommended.
5) Insert the power plug of the power adaptor into
⑨
POWER IN on the
back panel of the WAT-902H
2/3
SUPREME. Confirm that the power
adaptor is not connected to the power supply before insertion of the
power plug into
⑨
POWER IN.
6) Turn on the power to the WAT-902H
2/3
SUPREME, monitor and all
other allied equipment. When a picture cannot be obtained on the
monitor, or a problem occurs, check and follow the procedure mentioned
in the
【
Problems and Trouble Shooting
】
section.
7) After following the procedure below and the picture is still out of focus,
open the iris fully and loosen
④
FOCUSING ADJUSTMENT
SCREWS with the hex. wrench and move the lens forwards until a
clear picture is obtained.
Manual Lens
Adjust the focus and iris to the best
position on the lens.
Video Auto-iris Lens
Adjust the focus on the lens.
DC Auto-iris Lens
Adjust the iris level on the camera, then
adjust the focus on the lens. See
below.
Iris Level Adjustment (for DC auto-iris lenses)
Adjust
③
IRIS LEVEL VOLUME placed on the side
of the unit until an acceptable light level is attained.
No change will occur if a video iris lens or manual
iris lens is fitted.
8) Set the shutter mode by
⑦
AE MODE CONTROL.
(Shutter mode is set to EI upon shipment.)
AE Mode
Effect
EI
Automatically selects the shutter speed in the range
between EIA: 1/60-1/100000 sec., CCIR: 1/50-
1/100000 sec. according to the lighting condition.
FL
Reduces the flickering phenomena occurring on the
monitor screen caused by fluorescent or mercury
lamps.
OFF
Fixes the shutter speed to EIA: 1/60 sec., CCIR: 1/50
sec..
Warning
DC+12V
COMMON(GND)
Caution
Warning
Caution
Warning
Caution
Hex. Wrench