12 

Port Name   SN 

Name  

Note 

I/O Port  

ALARM_COM 

Alarm output public port.  

ALARM_NO 

Alarm  output  port.  It  is  to  output  the  alarm  signal 
to the alarm device.  

NO: normal open alarm output port.  

It works with the ALARM_COM port. 

ALARM_IN1 

Alarm input port 1. It is to receive the on-off signal 
from the external alarm source. 

ALARM_IN2 

Alarm input port 2. It is to receive the on-off signal 
from the external alarm source. 

GND 

Ground port  

 

2.2  Framework and Dimension 

Please note all frame and dimension illustrations provided in this chapter are for reference only, 

and actual product may vary. 

Please refer to Figure 2-2 or Figure 2-3 for dimension information according to the actual product. The 

unit is mm. Please also see Figure 2-4. 

 

Figure 2-2 Dimension illustration 1 

 

Содержание MPIX-21BIMR

Страница 1: ...i MPIX BIMR Network Camera With Integrated Bracket User s Manual...

Страница 2: ...r network camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this us...

Страница 3: ...cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by t...

Страница 4: ...nclosure when you are installing the device or clean the enclosure when you are doing maintenance work Please use professional optical clean method to clean the enclosure Improper enclosure clean meth...

Страница 5: ...ork and Dimension 12 2 3 Bidirectional talk 13 2 3 1 Device end to PC end 13 2 3 2 PC end to the Device end 13 2 4 Alarm Setup 14 3 Installation 16 3 1 Device Installation 16 3 2 Micro SD Card Install...

Страница 6: ...vi 4 2 Operation 21 5 Web Operation 24 5 1 Network Connection 24 5 2 Login and Main Interface 24 6 FAQ 27 7 Appendix Toxic or Hazardous Materials or Elements 28...

Страница 7: ...oup one user belongs to one group The user right shall not exceed the group right Storage Function Support central server backup function in accordance with your configuration and setup in alarm or sc...

Страница 8: ...has built in IR CUT mechanical component Auto Aperture Enable Gain Control Fixed Auto White Balance Manual Auto BLC Off BLC WDR 1 100 adjustable HLC anti flicker is outdoor and is valid only when exp...

Страница 9: ...k Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Network Protocol Standard HTTP TCP IP ARP IGMP ICMP RTSP RTP UDP RTCP SMTP FTP DHCP DNS DDNS PPPOE UPNP NTP Bonjour SNMP Remote Opera...

Страница 10: ...type General Encode mode H 264 Resolution 1080P 1920 1080 1 3M 1280 960 Frame Rate FPS PAL 25 NTSC 30 Bit Rate Type CBR Recommen ded Bit 3584 8192 Kb S 1536 8192Kb s Bit Rate 8192 6144 I Frame 50 Wate...

Страница 11: ...d Audio Main Stream Enable Enable Encode Mode G 711A Sub Stream Enable Disable Encode Mode G 711A Network TCP IP Host Name IPC Ethernet Card Wire Default Mode Static Mac Address Device MAC address whe...

Страница 12: ...rid com Domain Name none Username none Password Update Period 10 minutes IP Filter Trusted sites Disable SMTP Email SMTP Server none Port 25 Anonymity Disable User Name anonymity Password Sender none...

Страница 13: ...icast Address 239 255 42 42 Port 36666 Extra Stream Enable Disable Multicast Address 239 255 42 42 Port 36667 IEEE802 Enable Disable Authenticati on PEAP Username None Password QoS Real time Monitor 0...

Страница 14: ...y out Enable Alarm Delay 10 seconds Send Email Disable Snapshot Disable Abnormity No SD Card Enable Disable Relay out Enable Relay out Delay 10 seconds Send email Disable Capacity Warning Enable Disab...

Страница 15: ...ress N A Port 21 Username anonymity Password N A Remote path share Emergency Local Disable Record Control Pack Duration 8 minutes Pre record 5 seconds Disk Full Overwrite Record Mode Auto System Gener...

Страница 16: ...tup Item Default Setup MPIX 21BIMR NTP Server clock isc org Port 123 Update Period 10 minutes Account Anonymous Login Disable Auto Maintenance Auto Reboot Enable Tuesday 02 00 Auto Delete Old Files Di...

Страница 17: ...ion cable 2 Reset Reset port Hardware reset function Press it for 3 to 5 seconds system hardware can restore default setup 3 I O I O port Connect to I O port 4 LAN Network port Ethernet port Connect t...

Страница 18: ...gnal from the external alarm source 4 ALARM_IN2 Alarm input port 2 It is to receive the on off signal from the external alarm source 5 GND Ground port 2 2 Framework and Dimension Please note all frame...

Страница 19: ...on to enable the bidirectional talk function You can see the button becomes orange after you enabled the audio talk function Click Audio button again to stop the bidirectional talk function Listening...

Страница 20: ...e 2 Connect the alarm output device to the alarm output port No 2 pin and alarm output public port No 1 pin The alarm output port supports NO normal open alarm device only 3 Open the Web go to the Fig...

Страница 21: ...Port ALARM_COM and Port ALARM_NO composes an on off button to provide the alarm output If the type is NO this button is normal open The button becomes on when there is an alarm output If the type is...

Страница 22: ...steps listed below to install the device Please draw the installation holes in the installation surface and then mark three expansion bolts holes in the surface Insert three bolts in the hole and secu...

Страница 23: ...gure 3 7 according to the actual product The horizontal angle of the rear cover can rotate 360 the tilt angle can rotate 90 and the chassis can rotate 360 Please use the inner hex wrench to firmly sec...

Страница 24: ...18 Figure 3 3 Bracket adjustment 1...

Страница 25: ...D Buttons Please refer to the following contents for detailed information See Figure 3 5 and Figure 3 6 Top button Focus zoom in Bottom button Focus zoon out Left button Far Right button Near Middle b...

Страница 26: ...20 Figure 3 5 OSD button 1 Figure 3 6 OSD button 2...

Страница 27: ...ment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default...

Страница 28: ...rface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 3 In Figure 4 3 you can view device IP address user name password and port Please modify...

Страница 29: ...23 Figure 4 4 Main interface For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD...

Страница 30: ...IP address subnet mask and gateway of the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping n...

Страница 31: ...mation to ask you whether install web plug in or not after you logged in for one minute For detailed plug in installation please refer to the Web Operation Manual included in the resource CD After you...

Страница 32: ...26 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Страница 33: ...G SanDisk 4G Usually we recommend the 4GB or higher high speed card in case the slow speed results in data loss Audio function Please use active device for the audio monitor input otherwise there is n...

Страница 34: ...e toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodil...

Отзывы: