background image

 

14 

3.3. DISARMING 

 

When to use 

The system should be disarmed before entering the building or premise (there 
is no entry delay to the alarm).  

Indications 

The siren will beep twice and the blue  strobe  light will flash three times. The 
siren will beep 12 times if the alarm has been triggered while the system was 
armed.  

 
3.4. PANIC Mode 

 

When to use 

This mode should be used when the user wishes to activate the siren possibly 
used in an emergency situation. 

What happens 

The siren will sound and the blue light will flash to alert people in the area. 
 
 

3.8. The Passive Infrared Detector 

 
It is vital that the detector is tested carefully for each installation. At 
25°Celsius, the detector should have a detection range of approximately 10 
metres and a scope angle of 90°, i.e. 45° either side of the centre position 
straight ahead of the lens. 
 

3.8.4. Dual Edge Sensing (DES) technology ‘explained’ 

 

 

Figure 8 – side view, detection pattern in optimal temperature 

environment  

 

Содержание WGSENTINEL

Страница 1: ...Watchguard Sentinel Wireless Alarm System Model WGSENTINEL Document Watchguard Sentinel User Manual doc Release 15 July 2009 U s e r M a n u a l Designed in Australia Made in Taiwan By www rhino com au ...

Страница 2: ... 5 Adjusting the Detector Sensitivity 12 3 0 Turning the system on 13 3 1 Remote Control Functions 13 3 2 ARM Mode 13 3 3 DISARMING 14 3 4 PANIC Mode 14 3 8 The Passive Infrared Detector 14 3 8 4 Dual Edge Sensing DES technology explained 14 4 Programming 17 4 1 Adding New Remotes 17 4 2 Adding a Detector 18 4 3 Testing the Detector 19 4 3 1 Test Mode 19 5 Maintenance 20 5 1 The Remote Control 20 ...

Страница 3: ...Simple installation Hand held remote controls Remote functions include arm disarm and panic Ability to add or erase detectors from your system Up to 5 wireless devices can be used any combination of remotes or sensors Protects your family and property Suitable for home and office Powerful external siren with flashing blue warning light Main power adaptor with a 10m lead Latest technology Wireless ...

Страница 4: ...he two remotes are already pre learnt into your system no programming required 3 Power Supply plug pack 1 The main unit requires a regular mains power supply The Watchguard is supplied with a 12V DC plug pack that connects to the main unit s power connector on the end of the 10m cable 4 Passive Infrared Detector 1 Designed to detect the body movement of an intruder inside your premises These intel...

Страница 5: ...t 3 minutes before it will respond properly The wire which runs around the edge of the detector is the antenna Do not touch remove or cut this wire 1 3 The Strobe and Siren The siren strobe contains the main alarm unit for the Watchguard Sentinel Home Alarm System Functions The LED The LED will stay on when the unit is in learn mode When the unit is disarmed the LED will flash continuously at a sl...

Страница 6: ... range inside your house will be around 20 50 metres depending on the construction of the house Planning and Wire Routing 1 The Watchguard Sentinel main unit should be located high on the front or front side of the building under an eave of covering See Section 2 2 2 Route the white white black wire 2 core figure 8 cable from the main unit through the ceiling to connect with the plug pack connecto...

Страница 7: ...arming disarming Use the wall plugs and screws provided if suitable for your particular building construction Installing the main unit 1 Drill mounting holes 7mm diameter 25mm minimum in depth into the chosen wall 2 Use the green star plug Press each one into the 3 main mounting holes 3 Make a hole and push the wires through the wall and up into the ceiling 4 Screw the top 2 screws half way in 5 P...

Страница 8: ...nto the ceiling where the wire can go through to be connected to the wire from the main unit 2 Feed the wire through the hole in the ceiling and up to where it will join the wire from the main unit 3 Connect the connector from the power supply into the plug from the main unit as shown below Figure 4 ...

Страница 9: ...to the swivel bracket See diagram below Approx mounting angle at 2 1m Figure 5 2 4 1 Tips for positioning This detector utilises the very latest in detection processing technology to reduce the possibility of false alarms However correct mounting of the detector is critical to ensure best detection or catch performance You cannot just screw the detector directly to a wall up high in a corner and e...

Страница 10: ...above windows and doors to look inside DON T mount detector facing hot areas or areas where the temperature may change suddenly e g open fire places direct sunlight or air conditioning vents Select a location where the detector can provide the best detecting range Always ensure that you do not cover an area with multiple detectors so as to avoid simultaneous transmission back to the receiver in yo...

Страница 11: ...ponding then remove the batteries which the plastic was covering and slide the batteries back into their original position If after this you still don t have any response from the detector then the batteries may be flat I M P O R T A N T 2 4 3 Warm up period You must wait approximately 3 minutes for the detector to warm up after connecting the batteries This time starts from when the detector star...

Страница 12: ... 3 minutes and so on There is no need for the detector to trigger more than once every 3 minutes as your alarm system should be set to sound your siren for 5 minutes after being triggered In summary the detector will only trigger and flash the red light once every 3 minutes in its normal operation to save battery life The green light will stay off 2 4 5 Adjusting the Detector Sensitivity PULSE COU...

Страница 13: ...e button will arm or disarm the alarm system depending on the current state of the alarm That means if the alarm is armed then pressing the button would disarm it similarly if the alarm is disarmed then pressing the button would arm it PANIC mode Press and hold approximately 3 seconds to activate PANIC mode 3 2 ARM Mode When to use This mode is used when leaving the building or premise Arming the ...

Страница 14: ...e user wishes to activate the siren possibly used in an emergency situation What happens The siren will sound and the blue light will flash to alert people in the area 3 8 The Passive Infrared Detector It is vital that the detector is tested carefully for each installation At 25 Celsius the detector should have a detection range of approximately 10 metres and a scope angle of 90 i e 45 either side...

Страница 15: ...ment The detection pattern in an optimal temperature environment is shown in figure 9 Each time you walk into or out of an infrared beam zone this will be sensed and processed by the DES technology built into the detector The red trigger light will not turn on until the detector has made a valid movement detection in normal mode Figure 9 detection pattern in the optimal temperature environment ...

Страница 16: ... the opposite direction No trigger body movements Figure 11 no trigger No trigger body movements are body movements which are too small to be recognized as valid body movements to trigger the detector In the example shown by figure 11 a body walking into one side of the infrared beam zone then back out the same side of the infrared beam zone will not trigger the detector A body moving from positio...

Страница 17: ...has been learnt successfully immediately attempt to arm the system with the newly programmed remote Refer to Section 3 of this manual for remote operation instructions Your Watchguard Sentinel Home alarm System can only store a maximum of FIVE wireless devices in its memory If you learn in an 6th remote the 1st remote control will be erased If you lose a remote control or have one stolen or wish t...

Страница 18: ...ts in the detector will flash and the system will beep 4 times to signify that a valid detector has been learnt in 4 To test the detector wait 10 secs before pressing the tamper switch again If the detector is correctly learnt in pressing the tamper switch will activate the siren To stop the siren and disarm the system follow the disarming procedure outlined in section 3 1 of the manual ...

Страница 19: ...de Replace the front cover The detector will stay in test mode for 3 minutes The green and red lights will flash together 6 times to indicate that the detector is exiting test mode During test mode the detector will flash the green light when you move into an infrared beam zone or move out of the other side of that infrared beam zone see section 4 3 for more information on how the sensor detects m...

Страница 20: ...X27A Voltage 12 Volts 5 2 The Detector 5 2 1 Replacing the batteries The batteries can be removed by un clipping them out of the plastic battery holders The new batteries must be handled only by the edges as the chemicals in your skin may cause a poor battery connection Fingerprints can be cleaned off the batteries with a soft cloth and some alcohol solution The new batteries can now be slid into ...

Страница 21: ...pyro detector with the dampened cloth Be sure not to touch the pyro detector with you fingers 5 2 3 Cleaning the case and lens Detectors are often left in position for long periods and spiders or other pests might stay around the detector It is important that the lens especially is kept clean of any spider webs or pests from being in front of it It is recommended to keep the whole case clean by wi...

Страница 22: ...ave been improperly installed and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or garage fire Moreover smoke detectors have sens...

Страница 23: ...r warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for twelve months from the date of original purchase Sellers obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any part which is proved not in compliance with Sellers specific...

Страница 24: ...arranty made by Seller on this product No increase or alteration written or verbal of the obligations of this Limited Warranty is authorised NOTE In addition to the warranty conditions warranty will not be given where a product has been immersed in water under any circumstances or where damage has been caused by hosing the main unit without all due care taken by the owner to protect the main unit ...

Страница 25: ...uard System We take extreme care in the research design and development of our products to ensure they meet your needs Additionally we keep in close contact with our dealers worldwide and should any problem occur we will work closely with your local dealer to see that it is resolved quickly As a leading designer and manufacturer we are continually endeavouring to exceed the expectations of our cus...

Отзывы: