background image

V3.8 | EN | 17.05.23

13

Single gas detector

PDM 

Single gas detector

PDM 

9. LIMITED WARRANTY

WatchGas warrants this product to be free of defects in workmanship and materials-under nor-

mal use and service-for two years from the date of purchase from the manufacturer or from the 

product’s authorized reseller.

The manufacturer is not liable (under this warranty) if its testing and examination disclose that 

the alleged defect in the product does not exist or was caused by the purchaser’s (or any third 

party’s) misuse, neglect, or improper installation, testing, or calibrations. Any unauthorized at-

tempt to repair or modify the product, or any other cause of damage beyond the range of the 

intended use, including damage by fire, lightening, water damage or other hazard, voids liability 

of the manufacturer.

In the event that a product should fail to perform up to manufacturer specifications during the 

applicable warranty period, please contact the product’s authorized reseller or WatchGas service 

center at [email protected] for repair/return information.

WatchGas 

Klaverbaan 121

2908 KD Capelle aan den IJssel

The Netherlands

FOR MORE INFORMATION

www.watchgas.com

[email protected]

Содержание PDM

Страница 1: ...USER MANUAL Single gas detector PDM we watch gas where you can t...

Страница 2: ...5 3 3 Alarms Battery Test Failure display 6 3 4 Alarm Set Points 7 3 5 Default Calibration Concentrations 7 4 EVENT LOG 7 5 CALIBRATION 7 5 1 Fresh Air Calibration 7 5 2 Standard Gas Calibration 8 5...

Страница 3: ...of the device e g indoors vs outdoors the value of the measured gas concentration can suddenly change Please use the PDM after the gas concentration value has stabilized Severe vibration or shock to...

Страница 4: ...R communication port 1 PRODUCT OVERVIEW 3 6 1 2 4 DISPLAY SYMBOLS 5 6 7 Alarm Low Alarm High Alarm Stabilization Success Failure Fresh Air Calibration Standard Gas Calibration Remaining Months Remaini...

Страница 5: ...ion CAUTION Appropriate calibration of the device is required prior to operation Always ensure that the device makes the proper detection response to the pertinent gas Verify that debris that could in...

Страница 6: ...crease and the alarm will stop Alarm Alarm standard LCD Display Alarm and Vibration 1st Alarm Exceeds 1st alarm Icon concentration 2nd Alarm Exceeds 2nd alarm Icon concentration Remaining Life Below 3...

Страница 7: ...a WatchGas IR Link Each alarm event is recorded as follows Types of alarms Alarm concentration in ppm or Peak concentration 5 CALIBRATION CAUTION Initial calibration is performed on all devices prior...

Страница 8: ...5 2 STANDARD GAS CALIBRATION Attach the calibration adapter to the PDM and to a gas cylinder with a concentration matching the calibration concentration Check 3 1 Display Mode to check the calibratio...

Страница 9: ...ration always verify sensor response and alarm functionality prior to using the detector by applying a known concentration of gas from another gas cylinder 5 3 REMAINING CALIBRATION DAY In the standar...

Страница 10: ...ce the bump test interval expires Bts message will flash Put the PDM in the docking station with a valid and full gas cylinder Alternatively attach the calibration adapter to PDM and a valid and full...

Страница 11: ...Lithium Primary Battery SB AA02 P 3 6V 1 2Ah MEASUREMENT Diffusion HOUSING Polycarbonate and rubber ACCURACY DEVIATION 2 3 IP RATING IP67 SAFETY CERTIFICATIONS ATEX II 1G Ex ia IIC T4 Ga CSA Class 1...

Страница 12: ...S Ex ia IIC T4 KTL 16 KA2BO 0457 INMETRO Ex ia IIC T4 Ga BVC16 5919 02 Compliance Electromagnetic Compatibility Directive 2014 30 EU Standards The electrical apparatus and any acceptable variations to...

Страница 13: ...rty s misuse neglect or improper installation testing or calibrations Any unauthorized at tempt to repair or modify the product or any other cause of damage beyond the range of the intended use includ...

Отзывы: