WATANABE WPMZ-5 Скачать руководство пользователя страница 6

 

 

MODEL WPMZ-5-□□□-□□-□□□                                                                                 

 

6/12 

 

                                                                                                                                                                                                 

IM-0834-03 

8. 

 

BASIC OPERATIONS FOR SETTING DISPLAYS 

Basic operations for setting displays are shown as below. 
The following is an example for changing the voltage of sensor power supply. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 

 

By pushing the “MENU” key in the measurement mode, the display moves to the setting display and displays the 1st layer (major 

categories). 
By moving the cursor with “arrow key (UP/DOWN)”, the selection of major categories to set can be changed.   

*

 On the 1st layer, by pushing the “MENU” key, the display returns to the measurement display. 

 

Pointing the cursor to a major category to set and pushing “arrow key (RIGHT)”, the display moves to the 2nd layer (small categories)   

By moving the cursor with “arrow key (UP/DOWN)”, the selection of small categories of the setting can be changed. 
If the “arrow key (LEFT)” is pushed, the display returns to the 1st layer. 

*

 On the 2nd layer, by pushing the “MENU” key, the display returns to the measurement display. 

 

Pointing the cursor to a small category to set and pushing “arrow key (RIGHT)”, the display moves to the 3rd layer (setting items). 

If the “arrow key (LEFT)” is pushed, the display returns to the 2nd layer. 

*

 On the 3rd layer, by pushing the “MENU” key, the display returns to the measurement display. 

 

By moving the cursor with “arrow key (UP/DOWN)”, select a setting item.   

If the “arrow key (LEFT)” is pushed, the display returns to the 2nd layer. 

 

At  the  selected  setting  item,  by pushing  “arrow  key  (RIGHT)”,  the  display moves  to  the  4th  layer  (setting  contents)  and  a  current 

selected content has a check mark. If the “arrow key (LEFT)” is pushed, the display returns to the 3rd layer. 

 

By moving the cursor with “arrow key (UP/DOWN)”, select a content. 

If the “arrow key (LEFT)” is pushed, the display returns to the 3rd layer. 

 

By pushing the “ENTER” key”, the selected content is confirmed and a check mark accompanies. 

If the “arrow key (LEFT)” is pushed, the display returns to the 3rd layer. 

 

By pushing the “MENU” key, the selected content is stored and returns the measurement display. 

*

 If the power is shut down before being pushed the “MENU” key, the selected content is not stored. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

MENU

MENU

In any setting displays, the display returns to the 
measurenent display by pushing           .

MENU

MENU

(Measurement display)

1st layer

2nd layer

3rd layer

4th layer

or

or

Setting items can be selected by   

or

(Measurement 

display)

Содержание WPMZ-5

Страница 1: ...Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same duct with lines including noises might cause malfunctions 4 The WPMZ becomes available functionally right after power activation but requires 30 minutes warming to satisfy all performance requirements Note The inputs A channel and B channel may be ...

Страница 2: ...NE Ach Line driver input terminal 16 GND Ach GND input terminal 17 EXC Ach sensor power output terminal 18 EXC Ach sensor power output terminal 19 20 NC No connection Non usable for a relay terminal B channel line driver input terminal name description 21 LINE Bch Line driver input terminal 22 LINE Bch Line driver input terminal 23 GND Bch GND input terminal 24 EXC Bch sensor power output terminal...

Страница 3: ...tive Indicates comparative output reset function an external control function is effective Indicates measurement inhibit function an external control function is effective Indicates display hold function an external control function is effective Indicates maximum value or minimum value hold function an external control function is effective 5 2 2 Key Operation Icons On The Setting Display Key oper...

Страница 4: ...imes 8times 9times Set number of moving average Instantaneous value simple average InsSimpleAve None None 2 times 4 times 8 times 16 times 32 times 64 times 128 times 256 times Set number of simple average for internal sampling 10ms Instantaneous value display step InsDispStep None None 5steps 10steps Setting of steps of display If set to 5steps displayed only 0 or 5 on LSB WPMZ 5 L Pulse Input A ...

Страница 5: ...0bps 19200bps 38400bps Set baudrate Data length DataLength 8bit 7bit 8bit Set data character length Parity Parity None None Even Odd Set parity bit Stop bit Stopbit 1bit 1bit 2bit Set stop bit length Delimiter Delimiter CR CR CR LF Set delimiter type 3 Display Display Select Measure select MeasureSelect 1input InsA 2inputs InsA InsB InsA InsB InsCalc InsA InsB InsCalc A B InsA Comp InsB Comp InsCa...

Страница 6: ...ting items If the arrow key LEFT is pushed the display returns to the 2nd layer On the 3rd layer by pushing the MENU key the display returns to the measurement display By moving the cursor with arrow key UP DOWN select a setting item If the arrow key LEFT is pushed the display returns to the 2nd layer At the selected setting item by pushing arrow key RIGHT the display moves to the 4th layer settin...

Страница 7: ...r 1 pulse as instantaneous display coefficient Although instantaneous flow rate will be displayed in ℓ min the rating of the sensor is 7 5 mℓ Pulse it should be converted to 7 5 10 3 ℓ Pulse Set the Instantaneous display factor as 7 50000 10 3 Displayed unit is ℓ min therefore select Minute as the instantaneous unit time By instantaneous decimal point position set the number of digits after the de...

Страница 8: ...common for AL1 AL4 in open collector output products Each AL1 2 AL3 4 have common terminal in relay ouput products 11 3 COMPARISON JUDGEMENT VALUE The comparison judgement value is a threshold value to judge Although the setting procedure is same as 8 BASIC OPERATIONS FOR SETTING DISPLAY comparison judgement values need the settings of numerical values Therefore its procedure is shown below The fo...

Страница 9: ...d Bch 12 7 PATTERN SELECT FUNCTION The pattern select function is the function which switches the pattern number to use for measurement By using pattern select 1 3 Up to 8 patterns can be switched Function Name Selected pattern No pattern No in use 1 2 3 4 5 6 7 8 Pattern select1 Open Short Open Short Open Short Open Short Pattern select2 Open Open Short Short Open Open Short Short Pattern select3...

Страница 10: ...ys Please refer to 14 1 Locations of parameters for initialize 14 3 2 Initializing To User Defaults By executing to initialize to user defaults current setting values are replaced by user defaults Steps for the initialize operation are same as 14 2 Initializing to the factory defaults Operate the WPMZ according to the setting displays Please refer to 14 1 Locations of parameters for initialize 15 ...

Страница 11: ... structure IP66 front Installation environment indoor use Rated altitude up to 2000m Transient overvoltage Ⅱ Measurement category Ⅱ Pollution degree 2 Conformed EN standard EN61326 1 EMS industrial electromagnetic environment EMI Class A Applicable to line length only under 30m EN61010 1 EN50581 Material of enclosure polycarbonate PC black UL94V 0 Input Specifications Pulse input instantaneous mea...

Страница 12: ...ay value AL2 zone upper limit or AL2 zone lower limit display value AL2 display value AL3 zone upper limit or AL3 zone lower limit display value AL3 display value AL4 zone upper limit or AL4 zone lower limit display value AL4 Conversion method D A conversion method Resolution capability Equivalent of 13bit Scaling Digital scaling Output objective Response speed Specification for each output An ite...

Отзывы: