Wasserhaus QuaRO Series Скачать руководство пользователя страница 22

Wasserhaus Deutschland GmbH· Max-Wundel-Strasse 12 · D-14469 Potsdam · 

Tel. 0331 – 505 79 43 · Fax 0331 – 505 79 52 

www.wasserhaus.de · e-mail: [email protected] 

page 

22 

 

5. Remove the filter housings with the filter wrench supplied with unit by turning the 
housing to the left (counter clockwise). Be careful, as the housing can still contain 
some water. Be cautious that the o-ring seal remains seated in place inside the 
housing. 

 

6. Remove and discard the inner cartridges in a proper manner. Clean the inside of 
the bowl with the kitchen detergents and flash fresh water. 
7. Check to see if the o-ring is in its place and insert the new cartridges into the 
housing. Turn the housing to the right to reattach. Use the supplied housing wrench to 
tighten the housing just slightly beyond hand tight. DO NOT OVERTIGHTEN THE 
HOUSING. 
A higher frequency of filter changes may be necessary, dependent upon your feed 
water quality. You should inspect the filters periodically and maintain a service record 
to establish a maintenance schedule that is unique to your water conditions. 
8. Disinfect the storage tank as described on page 19.  
9. Open tank ball valve. 
10. Open cold water supply and brass water feeder handle and carefully flood the RO 
unit. 
11. Check system for leakages.  

 
How do I change the RO membrane?    

 
Caution
:  Do  not  drink  water  from  the  first  tank  produced  after  membrane  replacement. 
Make sure to shut off the water supply and drain the system.  

 
To change the membrane, stage 4, follow these instructions: 

1. Shut off the feed water to the system by turning handle of brass water feeder to 
close position. 
2. Empty water from the storage tank by opening faucet. 
3. Then close tank ball valve. 
4. Empty water from the RO unit by opening RO water faucet. 
5. Remove the 1/4" white poly line from the cap end of the membrane housing by 
following the instructions on page 13 of this manual (see: Disconnecting JG type 
Push-in Fittings) 
6. Unscrew the membrane cap by turning it counter clockwise until it is completely 
removed. Be sure that the O-ring remains properly seated on the collar of the 
housing. 

Содержание QuaRO Series

Страница 1: ...Max Wundel Strasse 12 D 14469 Potsdam Tel 0331 505 79 43 Fax 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 1 Installation and User Manual Residential Reverse Osmosis Water Filter Sys...

Страница 2: ...The pre filters remove sediment and chlorine from the water supply before they can enter the RO membrane The post filter removes any taste or odours that may remain in the water after passing through...

Страница 3: ...0 F 4 C min 100 F 38 C max Temperatures below the minimum will freeze and crack the R O membrane and filter housings Above 100 F 38 C the membrane will rapidly deteriorate The quality temperature and...

Страница 4: ...l This reverse osmosis system works on water pressure of 2 8 bar 32 psi minimum to 6 bar 87 psi maximum You must install a pressure reducing valve in the water supply pipe to the reverse osmosis syste...

Страница 5: ...he RO system will not make product water as it should and substantially reduced filter and membrane life will result CAUTION Chlorine in the water will destroy the RO membrane Most cities add chlorine...

Страница 6: ...x 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 6 5 Installation manual RECOMMENDED TOOLS Variable speed drill 1 8 7 16 and drill bit 4 6 10 or 13 drill bit 5 8 9 16 17 24 32 open en...

Страница 7: ...Wasserhaus Deutschland GmbH Max Wundel Strasse 12 D 14469 Potsdam Tel 0331 505 79 43 Fax 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 7 QuaRO Pur Parts Diagram...

Страница 8: ...Wasserhaus Deutschland GmbH Max Wundel Strasse 12 D 14469 Potsdam Tel 0331 505 79 43 Fax 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 8 QuaRO Power Parts Diagram...

Страница 9: ...Wasserhaus Deutschland GmbH Max Wundel Strasse 12 D 14469 Potsdam Tel 0331 505 79 43 Fax 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 9 QuaRO Plus Parts Diagram...

Страница 10: ...Membrane Housing Double O ring E Storage Tank 2 3 2 or 4 gallons F Inline Granular Carbon Cartridge G Inline Mineralizing Cartridge H Pressure Pump 1 Brass Water Feeder 3 8 or 2 Elbow JG 3 Elbow or C...

Страница 11: ...en when the storage tank is nearly full This dramatically improves the efficiency of the membrane and overall quality of your water as well as increasing the pressure and related volume of stored wate...

Страница 12: ...ple for a connection scheme of a permeate pump in QuaRO PUR ECO RO unit The permeate pump is connected in the same way in QuaRO PLUS system The only difference is the additional mineralization cartrid...

Страница 13: ...he pipe to check it is secure It is good practice to test the system prior to leaving site and or before use Disconnecting standard JG type push in fittings Disconnecting standard JG type push in fitt...

Страница 14: ...he installation is responsible for the compliance with effective regulations PLACE OF INSTALLATION Install the tank and the filter block in a vertical position under the sink If there is not enough sp...

Страница 15: ...each sump 1 8 turn to left and pull away from head to remove b Pull pre filters gently away from head remove shrink wrap and re install open end of pre filters on to head boss c To replace sumps alig...

Страница 16: ...e and turn it off 2 Open cold water faucet to release pressure and make sure there is no water running 3 Mount the brass water feeder 3 8 between cold water shut off valve and cold water tube to your...

Страница 17: ...t the complementary piece and clamp them together with the two bolts Tighten the two bolts evenly 5 Connect Black tubing to drain saddle valve Step 3 Installing the dispensing faucet The faucet should...

Страница 18: ...bit 4 Enlarge the hole using 7 16 bit Keep bit well oiled and cool then drill slowly 5 File or clean the surrounding area and remove the masking or duct tape NOTE the metal chips on porcelain will sta...

Страница 19: ...Micropur MC10 T capsule from the manufacturer Katadyn Before you start to mount the storage tank you must insert the disinfection capsule into the opening of the storage tank Then mount the tank ball...

Страница 20: ...or the water to flow through the system and purge all the air trapped inside the system 6 After 10 minutes turn the storage tank valve to the ON position handle is parallel to the tubing 7 Turn the RO...

Страница 21: ...h the newly installed system 10 Exchange of filters RO membrane CAUTION Any Replacement filters or membranes not recommended by the factory can cause severe damage to the system and void all warrantie...

Страница 22: ...s periodically and maintain a service record to establish a maintenance schedule that is unique to your water conditions 8 Disinfect the storage tank as described on page 19 9 Open tank ball valve 10...

Страница 23: ...ing of the membrane may need to be lubricated with a water soluble lubricant Then insert new membrane making sure it is fully seated into the bottom end and use your thumbs to apply pressure to the me...

Страница 24: ...ax 0331 505 79 52 www wasserhaus de e mail info wasserhaus de page 24 To change the post filter stage 5 follow these instructions 11 Service address Wasserhaus Deutschland GmbH Max Wundel Strasse 12 1...

Страница 25: ...product water Solution Replace the pre filter cartridge If the production rate does not improve replace the post filter stage 5 the RO membrane cartridge and the flow control valve Suggestion You sho...

Страница 26: ...oes not increase replace the post filter cartridge RO membrane cartridge and flow control valve on drain line Increase water pressure precondition the water etc as needed to conform before doing maint...

Страница 27: ...he storage tank or to the post filter and RO faucet Rejected water with the dissolved solids and organic matter is routed through the flow control valve and to the drain Storage tank The storage tank...

Отзывы: