Page 24 of 41
© 2003 Wasp Technologies, Inc.
POWER
ON
ACTIVE
STAND
POWER
FAILURE
SHUT
DOWN
BY
press [PWR]
wait on
keyin/scan
key in
bar code scan
RS232 input
press [PWR] (switch off)
press [PWR]
program running
NMI
(switch off)
(switch on)
Auto-off timeout
OR
call INT 22H
♦
Active
All system hardware is activated in
Active
mode. The system will
enter
Stand-by
mode if it waits on input or call INT 22H.
♦
Stand by
In the
Stand-by
mode, if a key is depressed, a bar code or RS-232
input occurs the WDT2200 will return to
Active
mode. Otherwise,
the portable terminal will enter
Shutdown
mode if the WDT2200 has
been idle for the specified timeout period as set in
AUTO OFF
.
♦
Shut Down
In
Shutdown
mode, the main power is cut off from the WDT2200
excluding its RAM and Real Time Clock.
NOTE: To conserve battery power, keep the WDT2200 in
STAND BY
mode
while waiting for input.
3.2.3.6 Password Definition
This function is used to create a password. The password is used to
prevent an unauthorized user from entering the
Supervisor mode
and
accidentally changing the WDT2200 configuration parameters. The
Password may consist of
maximum ten (10) alphanumeric characters
('A'-'Z', '0'-'9'). The Default password is
“2200
”.
At the User Mode menu:
1. Press 6 (6.PSWD)
2. Enter the new password
3. Press [ENT] to change the Password
OLD PASSWORD:
2200
NEW PASSWORD: