Keyboard Interface
Product Reference Guide
237
Keyboard Interface
Wedge Quiet Interval
Specifies the amount of time the reader looks for keyboard activity before it
breaks the keyboard connection in order to transmit data to host. The range
is from 0 to 990ms in 10ms increments.
This feature applies ONLY to the Keyboard Wedge interface.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode
to enter Prog. Mode.
4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure to set the Wedge Quiet Interval. See
for some examples of how to set this feature.
Table 33. Wedge Quiet Interval Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
10ms
150ms
600ms
850ms
2
Divide by 10 (and pad with
leading zeroes)
01
15
60
85
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT WEDGE QUIET INTERVAL SETTING
5
Scan Two Characters From
‘0’ and ‘1’
‘1’ and ‘5’
‘6’ and ‘0’
‘8’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Wasp WDI7500
Страница 1: ...Wasp WDI7500 Wasp WWS750 2D Duraline USB or Wireless Barcode Scanner Product Reference Guide...
Страница 10: ...viii Wasp WDI7500 WWS750 NOTES...
Страница 282: ...Sample Barcodes 272 Wasp WDI7500 WWS750 Sample Barcodes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...
Страница 308: ...Microsoft Windows Codepage 1252 Product Reference Guide 298 NOTES...