
ME
DE
DE
Wärtsilä 8L50DF
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
975
975
950
kW
Cylinder output
514
514
500
rpm
Engine speed
Fuel oil system
800±50
800±50
800±50
kPa
Pressure before injection pumps (PT 101)
8.3
8.3
8.0
m
3
/h
Fuel oil flow to engine, approx
16...24
-
16...24
-
16...24
-
cSt
HFO viscosity before the engine
140
-
140
-
140
-
°C
Max. HFO temperature before engine (TE 101)
2.0
2.0
2.0
cSt
MDF viscosity, min.
45
45
45
°C
Max. MDF temperature before engine (TE
101)
6.2
-
6.0
-
6.0
-
kg/h
Leak fuel quantity (HFO), clean fuel at 100%
load
31.1
15.5
30.1
16.0
30.1
16.0
kg/h
Leak fuel quantity (MDF), clean fuel at 100%
load
2...11
2...11
2...11
cSt
Pilot fuel (MDF) viscosity before the engine
400...800
400...800
400...800
kPa
Pilot fuel pressure at engine inlet (PT 112)
150
150
150
kPa
Pilot fuel outlet pressure, max
284
284
284
kg/h
Pilot fuel return flow at 100% load
Lubricating oil system (Note 5)
400
400
400
kPa
Pressure before bearings, nom. (PT 201)
800
800
800
kPa
Pressure after pump, max.
40
40
40
kPa
Suction ability, including pipe loss, max.
80
80
80
kPa
Priming pressure, nom. (PT 201)
63
63
63
°C
Temperature before bearings, nom. (TE 201)
78
78
78
°C
Temperature after engine, approx.
198
153
149
m
3
/h
Pump capacity (main), engine driven
145
145
145
m
3
/h
Pump capacity (main), electrically driven
125
125
125
m
3
/h
Oil flow through engine
45.0 / 45.0
45.0 / 45.0
45.0 / 45.0
m
3
/h
Priming pump capacity (50/60Hz)
11
11
11
m
3
Oil volume in separate system oil tank
0.5
0.5
0.5
g/kWh
Oil consumption at 100% load, approx.
1500
1500
1500
l/min
Crankcase ventilation flow rate at full load
19.5
19.5
19.5
m
3
Crankcase volume
500
500
500
Pa
Crankcase ventilation backpressure, max.
8.5...9.5
8.5...9.5
8.5...9.5
l
Oil volume in turning device
1.4
1.4
1.4
l
Oil volume in speed governor
HT cooling water system
250 + static
250 + static
250 + static
kPa
Pressure at engine, after pump, nom. (PT 401)
480
480
480
kPa
Pressure at engine, after pump, max. (PT 401)
74
74
74
°C
Temperature before cylinders, approx. (TE
401)
96
96
96
°C
Temperature after charge air cooler, nom.
180
180
180
m
3
/h
Capacity of engine driven pump, nom.
50
50
50
kPa
Pressure drop over engine, total
150
150
150
kPa
Pressure drop in external system, max.
3-6
Wärtsilä 50DF Product Guide - a16 - 9 September 2016
Wärtsilä 50DF Product Guide
3. Technical Data
Содержание WARTSILA 50DF
Страница 1: ...WÄRTSILÄ 50DF PRODUCT GUIDE ...
Страница 14: ...This page intentionally left blank ...
Страница 40: ...This page intentionally left blank ...
Страница 58: ...This page intentionally left blank ...
Страница 102: ...This page intentionally left blank ...
Страница 120: ...This page intentionally left blank ...
Страница 154: ...This page intentionally left blank ...
Страница 164: ...This page intentionally left blank ...
Страница 176: ...This page intentionally left blank ...
Страница 214: ...This page intentionally left blank ...
Страница 232: ...This page intentionally left blank ...
Страница 234: ...This page intentionally left blank ...
Страница 237: ......
Страница 238: ......
Страница 239: ......