Air separator (4S01)
It is recommended to install efficient air separators in addition to the vent pipes from the engine
to ensure fast evacuation of entrained air. These separators should be installed:
1 Directly after the HT water outlet on the engine.
2 After the connection point of the HT and LT circuits.
3 Directly after the LT water outlet on the engine if the HT and LT circuits are separated.
Fig 9-17
Example of air venting device (3V76C4757)
9.3.20
Expansion tank (4T05)
The expansion tank compensates for thermal expansion of the coolant, serves for venting of
the circuits and provides a sufficient static pressure for the circulating pumps.
Design data:
70 - 150 kPa (0.7...1.5 bar)
Pressure from the expansion tank at pump inlet
min. 10% of the total system volume
Volume
NOTE
The maximum pressure at the engine must not be exceeded in case an electrically
driven pump is installed significantly higher than the engine.
Concerning the water volume in the engine, see chapter Technical data.
9-18
Wärtsilä 50DF Product Guide - a16 - 9 September 2016
Wärtsilä 50DF Product Guide
9. Cooling Water System
Содержание WARTSILA 50DF
Страница 1: ...WÄRTSILÄ 50DF PRODUCT GUIDE ...
Страница 14: ...This page intentionally left blank ...
Страница 40: ...This page intentionally left blank ...
Страница 58: ...This page intentionally left blank ...
Страница 102: ...This page intentionally left blank ...
Страница 120: ...This page intentionally left blank ...
Страница 154: ...This page intentionally left blank ...
Страница 164: ...This page intentionally left blank ...
Страница 176: ...This page intentionally left blank ...
Страница 214: ...This page intentionally left blank ...
Страница 232: ...This page intentionally left blank ...
Страница 234: ...This page intentionally left blank ...
Страница 237: ......
Страница 238: ......
Страница 239: ......