3.2
Wärtsilä 8L34DF
ME
ME
DE
DE
AUX
AUX
Wärtsilä 8L34DF
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
500
500
500
480
500
480
kW
Cylinder output
750
750
750
720
750
720
rpm
Engine speed
4000
4000
4000
3840
4000
3840
kW
Engine output
2.2
2.2
2.2
2.2
2.2
2.2
MPa
Mean effective pressure
Variable
Constant
Constant
Constant
Constant
Constant
Speed mode
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
IMO compliance
Combustion air system (Note 1)
7.3
5.9
7.1
5.9
7.1
5.9
7.1
5.9
7.1
5.9
7.1
5.9
kg/s
Flow at 100% load
45
45
45
45
45
45
°C
Temperature at turbocharger
intake, max.
-
45
-
45
-
45
-
45
-
45
-
45
°C
Temperature after air cooler
(TE 601), load > 70%
-
55
-
55
-
55
-
55
-
55
-
55
°C
Temperature after air cooler
(TE 601), load 30...70%
50
-
50
-
50
-
50
-
50
-
50
-
°C
Temperature after air cooler
(TE 601)
Exhaust gas system (Note 2)
7.5
6.1
7.4
6.1
7.4
6.1
7.4
6.1
7.4
6.1
7.4
6.1
kg/s
Flow at 100% load
5.8
5.0
5.9
5.1
5.9
5.1
5.9
5.1
5.9
5.1
5.9
5.1
kg/s
Flow at 75% load
4.2
4.0
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
kg/s
Flow at 50% load
362
381
370
381
370
381
346
362
381
381
355
362
°C
Temperature after turbochar-
ger at 100% load (TE 517)
349
386
340
401
340
401
318
383
349
401
327
383
°C
Temperature after turbochar-
ger at 75% load (TE 517)
333
341
360
402
366
402
346
386
371
402
350
386
°C
Temperature after turbochar-
ger at 50% load (TE 517)
4
4
4
4
4
4
kPa
Backpressure, max.
700
638
696
638
696
638
683
629
702
638
688
629
mm
Calculated exhaust diameter
for 35 m/s
Heat balance at 100% load (Note 3)
591
497
567
496
567
496
542
476
573
496
547
476
kW
Jacket water, HT-circuit
1288
801
1244
801
1244
801
1244
801
1244
801
1244
801
kW
Charge air, HT-circuit
245
228
238
228
238
228
238
228
238
228
238
228
kW
Charge air, LT-circuit
375
347
348
347
348
347
333
333
352
346
336
333
kW
Lubricating oil, LT-circuit
164
160
162
160
162
160
155
154
163
160
156
154
kW
Radiation
Fuel consumption (Note 4)
-
7470
-
7470
-
7470
-
7470
-
7470
-
7470
kJ/kWh
Total energy consumption at
100% load
-
7570
-
7620
-
7620
-
7620
-
7620
-
7620
kJ/kWh
Total energy consumption at
85% load
-
7590
-
7850
-
7850
-
7850
-
7850
-
7850
kJ/kWh
Total energy consumption at
75% load
-
7790
-
8600
-
8600
-
8600
-
8600
-
8600
kJ/kWh
Total energy consumption at
50% load
-
7387
-
7387
-
7387
-
7387
-
7387
-
7387
kJ/kWh
Fuel gas consumption at
100% load
Wärtsilä 34DF Product Guide - a16 - 23 September 2016
3-5
3. Technical Data
Wärtsilä 34DF Product Guide
Содержание WARTSILA 34DF
Страница 1: ...WÄRTSILÄ 34DF PRODUCT GUIDE ...
Страница 20: ...This page intentionally left blank ...
Страница 50: ...This page intentionally left blank ...
Страница 58: ...This page intentionally left blank ...
Страница 98: ...This page intentionally left blank ...
Страница 142: ...This page intentionally left blank ...
Страница 152: ...This page intentionally left blank ...
Страница 160: ...This page intentionally left blank ...
Страница 192: ...This page intentionally left blank ...
Страница 198: ...This page intentionally left blank ...
Страница 204: ...This page intentionally left blank ...
Страница 218: ...This page intentionally left blank ...
Страница 224: ...This page intentionally left blank ...
Страница 226: ...This page intentionally left blank ...
Страница 229: ......
Страница 230: ......
Страница 231: ......