background image

 

  Never  disconnect  the  plug  to  stop  compressor,  set  the  switch  knob  to  the  OFF   

position.

 

  If the release valve doesn’t work when motor stopped, find the cause immediately so 

as not to damage motor. 

  Lubricating oil must be clean, oil level should be kept in red circle of the oil leveler. 

  Before restarting the motor press the reset button and check the air   

compressor carefully, check the pressure in the air tank and make sure it is under 0.8Mpa.   

  Always  disconnect  the  plug  to  cut  off  power  supply  and  open  the  outlet  valve  and 

discharge all air in the air tank after use. 

 

6. MAINTENANCE 

  Before maintenance operation, stop the air compressor, cut off power supply and 

discharge all air in the air tank.   

  Clean crank case and renew lubricating oil after the first 10 working hours. 

  Check the oil level after every 20 working hours, 

and replenish if necessary (Fig.5).   

  Clean  crank  case  and  renew  the  oil,  clean  air 

filter every three months.   

  Open  the  drain  cock  under  the  tank  to  exhaust 

the  condensation  after  every 

60

  working  hours  but 

less than every

 7

 days. 

  Check  the  safety  valve  and  pressure  gauge  by 

professional organization every 6 months and make 
sure they are in correct condition. 

  Make sure there is no rust on the air tank and the air tank is not damaged. 

  Check  the  thickness  of  the  air  tank  by  professional  organization  every  year  and 

make sure the thickness is not less than 2.1mm. 

 
 

Fig.5 

Отзывы: