3. PREPARATION FOR STARTING 

  Check  all  bolts  and  nuts.  Make  sure  all  parts  that  are 

loose must be tightened. 

  The  place  to  set  the  compressor  should  be  clean,  dry 

and ventilated. 

  Keep the using voltage within 

±

4% of the rated.     

  Keep the oil level in the red circle of the oil leveler. 

  Recommend SAE30 or  L-DAB100 over 10

, and use 

SAE10 or L-DAB68 below 10

  of the compressor oil.   

  Open the outlet valve, set the knob of pressure switch in 

position on (Fig.2), let the compressor run 10 minutes with 
no  load  to  ensure  lubricating  the  moving  parts  before 
regular service. 
 

4. OPERATION AND ADJUSTMENT 

  The  compressor  is  controlled  by  a  pressure  switch  on  start  up.  It  will  stop 

automatically  as  pressure  increases  to  the  maximum 
and  restarts  automatically  as  pressure  decreasing  to 
the minimum. The rated pressure has been factory set 
and  MUST  not  be  altered.  As  soon  as  motor  is 
switched off, the compressed air in the discharge pipe 
should be released through the pressure release valve. 
This  is  a  necessary  proceedure  for  the  restart  or 
storage as the motor could result in damage.   

  The  output  pressure  of  compressed  air  can  be 

adjusted by  the regulating  valve.  Pull up  the knob of 
regulation valve and turn it clockwise to increase  and 
counter clockwise to decrease the pressure (Fig.3). 

  When the compressor in running and is needed to be stopped press the ON/OFF 

switch to the OFF position.   

 

5. CAUTIONS 

  Before  compressor  is  started  and  ran  you  MUST 

install    Air  Filter  and  oil  hole  plug  (Breather  pipe) 
(Fig.4).   

  Never unscrew any parts or take out oil hole plug 

in a pressurised condition or when in operation. 

Never  disassemble  any  electrical  part  before 

disconnecting the plug from the mains. 

  Never adjust the safety valve. 

  Never use the compressor in place where voltage is too low or too high. 

  Never use an extension electric lead more than 5m long with less than 1.5mm2 core. 

Fig.3 

Fig.2 

Fig.4 