WPE DIESEL GENERATORS
TROUBLESHOOTING
9
EN
TROUBLESHOOTING
Problem
Cause
Solution
Engine will not start.
No fuel.
Add fuel.
The switch is not at “ON” position
Turn it to “ON” position
The high pressure fuel pump,
injection nozzle cannot inject or
the fuel amount is insufficient.
Remove the injection nozzle out and repair
it or bleed the fuel injection system.
The control lever of speed is not at
“RUN” position
Put the control level to “RUN” position
Check oil level
Add oil if needed
The speed and force to pull the
recoil starter is not enough
Start the diesel engine according to the
requirements of operating procedure of
start
The injection nozzle is dirty or
blocked
Clean or replace injection nozzle
The battery is flat
Recharge or replace
Engine will not start with Remote
Control.
Ignition key is not in the ON
position
Check steps 1-3 on RC instructions
Lever not in to RUN position Check steps 1-3 on RC instructions
Oil or fuel level low
Add oil or fuel if needed
Engine is running but no output.
AC circuit breaker is turned ‘OFF’
Put the main AC switch to the “ON” position
The contact of socket is not good
Adjust the feet of socket
The rated speed of generator
cannot be reached
Adjust engine governor according to the
requirements
Other.
Contact Technical Support
44(0)1942 715 407.
NOTE: When welding, if you find the electricity is too large for welder or the engine shuts down by overload during
welding, it may cause by the AVR’s regulator to damage or short circuit.
Содержание 6000S
Страница 77: ...WIRING DIAGRAM WPE Diesel Generators Wiring Diagram 77 EN...
Страница 79: ...ENGINE PARTS LIST WPE Diesel Generators ENGINE PARTS LIST 79 EN...
Страница 80: ...PARTS DIAGRAM WPE Diesel Generators PARTS DIAGRAM 80...
Страница 81: ...PARTS LIST WPE Diesel Generators PARTS LIST 81 EN...