Warren rupp SANDPIPER MSA3 Скачать руководство пользователя страница 2

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly grounded 

in accordance with local electrical codes. Pumps equipped with electrically conductive diaphragms are suitable for 

the transfer of conductive or non-conductive fluids of any explosion group. When operating pumps equipped with 

non-conductive diaphragms that exceed the maximum permissible projected area, as defined in EN 13461-1: 2009 

section 6.7.5 table 9, the following protection methods must be applied:

•  Equipment is always used to transfer electrically conductive fluids or

•  Explosive environment is prevented from entering the internal portions of the pump, i.e. dry running

For further guidance on ATEX applications, please consult the factory.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure during 

operation. Make certain that all fasteners are in good condition 

and are reinstalled properly during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

Grounding ATEX Pumps

Use safe practices when lifting

kg

R E C YC L I N G 

Many components of SANDPIPER

®

 AODD 

pumps are made of recyclable materials.  

We encourage pump users to recycle worn 

out parts and pumps whenever possible, 

after any hazardous pumped fluids are  

thoroughly flushed.

WARNING

The use of non-OEM replacement parts will void (or negate) 

agency certifications, including CE, ATEX, CSA, 3A and EC1935 

compliance (Food Contact Materials).  Warren Rupp, Inc. cannot 

ensure nor warrant non-OEM parts to meet the stringent 

requirements of the certifying agencies. 

Содержание SANDPIPER MSA3

Страница 1: ...Lubrication 2 ESADS Plus Externally Serviceable Air Distribution System 2 Pilot Valve 3 Pilot Valve Actuator 3 Air Exhaust 3 Between Uses 3 Check Valve Servicing 3 Diaphragm Servicing 3 Reassembly 3...

Страница 2: ...uld be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket c...

Страница 3: ...h end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chambers are ma...

Страница 4: ...oving four hex head capscrews each end on the end caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and mu...

Страница 5: ...haust higher than the product source to prevent siphoning spills Freezing or icing up of the air exhaust can occur under certain temperature and humidity conditions Use of a Warren Rupp Extractor Drye...

Страница 6: ...Air will escape out discharge line in this case D Blockage in diaphragm chamber preventing movement Shut off air supply and reopen after pressure is relieved E Plugged or dirty exhaust muffler PROBLEM...

Страница 7: ...4 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375...

Страница 8: ...4 20 X 3 4 8 17 170 034 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8 18 170 045 330 CAPSCREW HEX HEAD 4 19 170 066 330 CAPSCREW HEX 1 2 13 X 2 25 36 20 172 001 330 CAPSCREW SOCKET 12 21 196 003 155 CHAM...

Страница 9: ...48 620 011 114 PLUNGER ACTUATOR 2 49 670 006 115 RETAINER FLAP VALVE 4 50 685 008 120 ROD DIAPHRAGM 1 51 720 004 360 SEAL U CUP 2 52 722 007 010 SEAT FLAP VALVE 4 53 807 016 330 7 16 14 STUD 12 54 807...

Страница 10: ...17 34 23 22 24 31 21 32 5 A 5 D 33 4 18 5 F 5 E 50 11 39 48 15 36 30 37 55 49 42 52 29 54 52 53 27 35 25 26 58 19 2 7 17 56 36 5 B 5 C 16 12 9 60 44 61 38 6 28 10 40 1 47 8 41 56 13 19 57 46 30 29 51...

Страница 11: ...98 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 12: ...knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09A...

Отзывы: