background image

f10mdl1sm-rev0219

sandpiperpump

.

com

2

 • Model F10 Metallic 

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure 

during operation. Make certain that all fasteners and piping 

connections are in good condition and are reinstalled properly 

during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

WARNING

Pump not designed, tested or certified to be powered by 

 

compressed natural gas. Powering the pump with natural  

gas will void the warranty.

Use safe practices when lifting

kg

WARNING

The use of non-OEM replacement parts will void (or negate) 

agency certifications, including CE, ATEX, CSA, 3A and EC1935 

compliance (Food Contact Materials).  Warren Rupp, Inc. cannot

 

ensure nor warrant non-OEM parts to meet the stringent 

requirements of the certifying agencies. 

ATEX Pumps - Conditions For Safe Use

1. 

 

Ambient temperature range is as specifi ed in tables 1 & 2 on the next page

2.  

ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly grounded in  

   

accordance with local electrical codes

3. 

 

Conductive Polypropylene, conductive Acetal or conductive PVDF pumps are not to be installed in applications where the  

   

pumps may be subjected to oil, greases and hydraulic liquids.

4. 

 

When operating pumps equipped with non-conductive diaphragms that exceed the maximum permissible projected area,  

   

as defi ned in EN ISO 80079-36 : 2016 section 6.7.5 table 8, the following protection methods must be applied

   

- Equipment is always used to transfer electrically conductive fl uids or 

   

- Explosive environment is prevented from entering the internal portions of the pump, i.e. dry running.

Содержание Sandpiper F10

Страница 1: ...nit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certified 1935 2004 EC 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 WARRANTY SERVICE OPERATING MANUAL Original Instructions ...

Страница 2: ...an appropriate area for safe containment This pump is pressurized internally with air pressure during operation Make certain that all fasteners and piping connections are in good condition and are reinstalled properly during reassembly Take action to prevent static sparking Fire or explosion can result especially when handling flammable liquids The pump piping valves containers and other miscellan...

Страница 3: ...C to 108 C T4 T135 C 20 C to 160 C T3 T200 C 20 C to 177 C 225 C T2 Table 1 Category 2 ATEX Rated Pumps Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C Table 2 Category M2 ATEX Rated Pumps for Mining Note The ambient temperature range and the process temperature range should not exceed the operating temperature range of the applied plastic parts as listed in the ...

Страница 4: ...N OPERATION 9 Principle of Pump Operation Recommended Installation Guide Troubleshooting Guide SECTION 3 EXPLODED VIEW 12 Composite Repair Parts Drawing Service Repair Kits Composite Repair Parts List Material Codes SECTION 7 WARRANTY CERTIFICATES 14 Warranty CE Declaration of Conformity Machinery CE Declaration of Conformity EC Regulation 1935 2004 EC 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 WARRANT...

Страница 5: ...tainless Steel Diaphragm Check Valve Materials D FDA Santoprene PTFE H FDA Hytrel FDA Hytrel K PTFE with FDA Hytrel Backer PTFE Z PTFE One Piece Bonded Fusion Diaphragm PTFE Your Serial fill in from pump nameplate ______________________________________ Pump Pump Check Design Wetted Diaphragm Check Valve Non Wetted Porting Pump Muffler Pump Brand Size Valve Level Material Check Valve Seat Material ...

Страница 6: ...6 7 8 9 10 BAR 1 Bolted Metal TPE Fitted Flow Rate Adjustable to 0 49 gpm 185 5 lpm Port Size Suction 1 SANITARY CLAMP Discharge 1 SANITARY CLAMP Air Inlet 3 8 NPT Air Exhaust 1 2 NPT Suction Lift Dry 16 4 9 m Wet 31 9 4 m Max Solid Size Diameter 1 8 3 1 mm Max Noise Level 93 dB A Shipping Weights Stainless Steel 36 lbs 16 3 kg 1 Bolted Metal PTFE Fitted Flow Rate Adjustable to 0 38 gpm 136 3 lpm ...

Страница 7: ...in EPDM Shows very good water and chemical resistance Has poor resistance to oils and solvents but is fair in ketones and alcohols 280 F 138 C 40 F 40 C Hytrel Good on acids bases amines and glycols at room temperatures only 220 F 104 C 20 F 29 C Santoprene Injection molded thermoplastic elastomer with no fabric layer Long mechanical flex life Excellent abrasion resistance 275 F 135 C 40 F 40 C Vi...

Страница 8: ...sions on this drawing are for reference only A certified drawing can be requested if physical dimensions are needed AIR INLET SUCTION SANITARY CLAMP FLANGE DISCHARGE SANITARY CLAMP FLANGE AIR EXHAUST 1 UPDATED TO CURRENT DESIGN CHG DATE ECN PART NUMBER D C B A E1SJxxxx91 FP ATE ELECTROPOLI ALL DIAPHRAG NICKLE PLATE 1 1 2 1 1 2 AIR EXHAUST C 1 D B 1 PUMP SPECS ...

Страница 9: ...de check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulled through its stroke The diaphragm s inner plate makes contact with an actuator plunger aligned to shift the pilot signaling valve Once actuated the pilot valve sends a pressure signal to the opp...

Страница 10: ...operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to increase air flow as desired If opening the valve increases cycling rate but does not increase the rate of flow cavitation has occurred The valve should be closed slightly to obtain the m...

Страница 11: ...point of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Check suction move pump closer to product Lack of air line size PSI CFM Check the air line...

Страница 12: ...180 in lbs 20 N m Torque Setting 180 in lbs 20 N m Torque Setting 40 in lbs 4 N m 476 378 351 Wet End Kit Santoprene Diaphragms PTFE Check Balls PTFE Seat O Rings 476 378 350 Wet End Kit FDA Hytrel Diaphragms FDA Hytrel Check Balls PTFE Seat O Rings 476 378 663 Wet End Kit FDA Hytrel Diaphragms PTFE Diaphragms PTFE Check Balls PTFE Seat O Rings 476 378 659 Wet End Kit 1 Piece PTFE Diaphragms PTFE ...

Страница 13: ...m 13 775 V005 000 13 7 Pilot Spool O Rings 560 023 358 14 1 Pilot Valve Sleeve ASY includes item 15 755 V004 000 15 6 Pilot Valve Sleeve O Rings 560 101 358 16 2 Shaft Pilot Retainer 670 V002 554 10 4 Retainer Screw S1001 17 1 Muffler VTM 4A Diaphragm Assembly Elastomers Item Qty Description Part Number FDA Hytrel FDA Santoprene PTFE 2 Piece PTFE Fusion 18 2 Main Shaft O Ring P50 403 19 1 Main Sha...

Страница 14: ...EN809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that no product sold by Warren Rupp that bears a Warren Rupp brand shall fail under normal use and service due to a defect in material or workmanship within five years from the date of shipment from Warre...

Страница 15: ...F600 F30B1SKSNTF600 F30B1SZSNTF600 Food Processing Pump Models Tranquilizer Surge Suppressors T15B1SSTSTS600 T20B1SASWTS600 T20B1SDSWTS600 T20B1SASSTS600 T20B1SDSSTS600 T20B1SASWTS600 T20B1SDSWTS600 T20B1SASSTS600 T20B1SDSSTS600 T30B1SASWTS600 TA1 NG1SS TA25 NG1SS TA1 1 2 NG1SS TA40 NG1SS F10B1SZSNTF600 F10B1SDSNTF600 F15B1SKSNTF600 F15B1SKTNTF600 F15B1SZSNTF600 F15B1SHHNTF600 F15B1SDDNTF600 F15B1...

Страница 16: ...ies ST Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex h IIC T5 225 C T2 Ga II 1 D Ex h IIIC T100 C T200 C Da II 2 G Ex h ia IIC T5 Gb II 2 D Ex h ia IIIC T100 C Db II 2 G Ex h mb IIC T5 Gb II 2 D Ex mb tb IIIC T100 Db Metallic pump models with no external aluminum S series HD Series G...

Отзывы: