6
3) PARAMETER SELECT / ADJUST KNOB :-
A) TO SELECT ONE OF THE PAREMETERS ONE BY ONE FROM PRE
FLOW TO POST FLOW THE PARAMETER SELECT / ADJUST KNOB
HAS TO BE PRESSED.
B) AFTER SELECTING ONE OF THE PARAMETER USING THE
PARAMETER SELECT / ADJUST KNOB, THE SAME KNOB HAS TO
BE ROTATED TO SET THE DESIRED PARAMETER.
TO INCREMENT THE PARAMETER THE KNOB HAS TO BE
ROTATED CLOCK WISE. TO DECREMENT THE PARAMETER THE
KNOB HAS TO BE ROTATED ANTI CLOCK WISE.
4)
DISPLAY :-
A) VOLT METER DISPLAY :- VOLT METER DISPLAY IS FOR
DISPLAYING THE WELDING VOLTAGES.
B) CURRENT METER DISPLAY :- CURRENT METER DISPLAY IS FOR
DISPLAYING THE WELDING CURRENT.
5) PARAMETER RANGE :-
S.NO PARAMETER.
MINIMUM.
MAXIMUM.
1
PRE FLOW.
00.0 SECONDS.
5.0 SECONDS.
2
START CURRENT.
00.0 AMPEARS
400 AMPEARS
3
UP SLOPE
00.0 SECONDS.
10.0 SECONDS.
4
WELDING CURRENT.
5 AMPEARS.
400 AMPEARS.
5
PULSE FREQUENCY.
00.1Hz.
99.9 Hz.
6
DUTY CYCLE.
25 %.
50 %.
7
BASE CURRENT.
5 AMPEARS.
400 AMPEARS.
8
DOWN SLOPE.
00.0 SECONDS.
10.0 SECONDS.
9
STOP CURRENT.
5 AMPEARS.
400 AMPEARS.
10
POST FLOW.
00.0 SECONDS.
60 SECONDS.