1.4.2
“Protection” indicator lamp:
lights on yellow and stops
welding automatically while in overheat, over-current,
over-voltage or water insufficient, but will not light on
while in normal welding. Protection codes are illustrated
below:
1.
Display 801: Over-voltage protection. Please turn off welder
immediately and inform authorized reseller to repair.
2.
Display 802 or 803: Over-current protection. Please turn off
welder immediately and inform authorized reseller to repair.
3.
Display 804: overheat protection. Please turn off welder
immediately to cool it down.
4.
Display 805: Pulling torch trigger for a long time with no
current or torch damaged. Repair welding torch or foot pedal
5.
Display 806(500,630 types): water insufficient protection.
The default setting is “water cooled”. It does work while using a
water-cooled torch at normal water circulation. When applied
air-cooled torch, the welder’s protection lamp will light on and
display “806” protection code. Press the Function selection and
parameter preset knobs simultaneously for up to 3 seconds to
eliminate water insufficient protection. Redo the same way to
back to previous mode.
1.4.3
Power on/off lamp:
It displays red when power on