background image

Warner Electric • 800-825-9050

P-209-WE • 819-0517 

  

9

PB-825 

Brake–Heavy 

Duty 

      Drawing 

I-25567

1

Shipped  As sem bled

2

3

5A

4

5B

6A

6A-1

6B

6B-1

7

1-3

1-4

1-2

1-1

1-5

7

Item

Description

PB-825, H.D. Part Number

Qty.

1

Armature Assembly

5321-111-001

1

1-1

Armature

5321-111-022

1

1-2

Splined Adapter

104-0008

1

1-3

Autogap Accessory

5321-101-006

1

1-4

Screw

797-0272

3

1-5

Locknut

661-0004

3

2

Bushing
1/2” to 1-1/2” Bore

180-0002 to 180-0018*

1

3/4” to 2-11/16” Bore

3

Splined Hub

540-0057

1

4

Retainer Ring

748-0006

1

5A

Mounting Accessory - I .M .

5321-101-001

1

5B

Mounting Accessory - O .M .

5321-101-002

1

6A

Magnet - Inside Mounted

1

6 Volt

5311-631-002

24 Volt

5311-631-003

90 Volt

5311-631-004

†90 Volt LK Facing

5311-631-011

6A-1

Terminal Accessory

5311-101-001

1

6B

Magnet - Outside Mounted

1

6 Volt

5311-631-007

24 Volt

5311-631-009

90 Volt

5311-631-008

†90 Volt LK Facing

5311-631-012

Item

Description

PB-825, H.D. Part Number

Qty.

6B-1

Terinal Accessory

5311-101-001

1

7

Conduit Box

5200-101-011

1

*See page 16 for specific part numbers . †Optional LK facing available .

How to Order:

1 . Specify Bore Size for Item 2 .

2 .  Specify Inside Mounted for Items 5A and 6A or 

Outside Mounted for Items 5B and 6B .

3 . Specify Voltage for Item 6A or 6B .

4 . See P-1264-WE for Power Supplies .

Example:

PB-825 Brake per I-25567 - 90 Volt, 1” Bore, Inside 
Mounted

These units, when used in conjunction with the 
correct Warner Electric conduit box, meet the 
standards of UL508 and are listed under guide card 
#NMTR, file #59164 . These units are CSA certified 
under file #LR11543 .

Содержание PB-825

Страница 1: ...Primary Brake Spline Drive Armature PB 825 PB 1000 PB 1225 PB 1525 Installation Instructions P 209 WE 819 0517...

Страница 2: ...12 PB 1525 14 Bushings 16 Warranty Back Cover Follow the installation instructions in this manual carefully to ensure safe reliable operation All stated or implied manufacturer warranties are voided i...

Страница 3: ...d the magnet within the required tolerances See Figure 1 2 A machined pilot diameter is provided on the magnet mounting flange refer to illustration drawings on page 8 10 12 or 14 to aid in the proper...

Страница 4: ...ve down through the autogap spring and splined armature adapter See Figure 4 Step 3 Turn the armature adapter assembly over and insert the retainer ring in the groove See Figure 5 Step 4 Slide the arm...

Страница 5: ...the armature is released it will spring back about 1 32 The gap will be automatically maintained for the life of the unit See Figures 9 10 Figure 9 Figure 8 1 32 inch Armature Magnet Figure 10 Coil Da...

Страница 6: ...cessary to remachine the worn magnet face In refacing a magnet 1 machine only enough material to clean up the complete face of the magnet 2 hold the face within 005 of parallel with the mounting plate...

Страница 7: ...the 6 volt series These readings are with the power on and the potentiometer control in the maximum position Ohmmeter checks should be made with the power off and the circuit open to be certain discon...

Страница 8: ...true position relative to pilot diameter Magnet View Inside Outside Mounted See page 16 for details on Bushings 2 500 531 1 312 562 Max 5 656 921 1 546 5 16 18 UNC 3A 062 156 8 656 Max Dia 1 250 1 76...

Страница 9: ...Volt 5311 631 004 90 Volt LK Facing 5311 631 011 6A 1 Terminal Accessory 5311 101 001 1 6B Magnet Outside Mounted 1 6 Volt 5311 631 007 24 Volt 5311 631 009 90 Volt 5311 631 008 90 Volt LK Facing 531...

Страница 10: ...relative to pilot diameter Magnet View Inside Outside Mounted Armature View See page 16 for details on Bushings 4 093 500 1 453 562 Max 6 531 921 1 546 5 16 18 UNC 3A 062 234 10 328 Max Dia 2 500 2 68...

Страница 11: ...Volt 5312 631 006 90 Volt LK Facing 5312 631 001 6A 1 Terminal Accessory 5311 101 001 1 6B Magnet Outside Mounted 1 6 Volt 5312 631 011 24 Volt 5312 631 013 90 Volt 5312 631 012 90 Volt LK Facing 5312...

Страница 12: ...hin 010 of true position relative to pilot diameter Magnet View 5 16 18 UNC 3A 562 1 640 562 7 531 921 1 546 062 234 4 093 Dia 12 671 Max Dia 2 500 2 687 4 167 Max See page 16 for details on Bushings...

Страница 13: ...631 006 90 Volt 5313 631 007 90 Volt 5313 631 001 6A 1 Terminal Accessory 5311 101 001 1 6B Magnet Outside Mounted 1 6 Volt 5313 631 010 24 Volt 5313 631 012 90 Volt 5313 631 011 90 Volt 5313 631 002...

Страница 14: ...within 010 of true position relative to pilot diameter Armature View 5 16 18 UNC 3A 562 1 750 562 9 187 921 1 546 062 234 4 093 Dia 15 609 Max Dia 2 500 2 687 4 281 Max 358 338 dia 9 002 9 000 Pilot...

Страница 15: ...O M 6A Magnet Inside Mounted 1 6 Volt 5314 631 004 24 Volt 5314 631 006 90 Volt 5314 631 005 90 Volt 5314 631 001 6A 1 Terminal Accessory 5311 101 001 1 6B Magnet Outside Mounted 6B 1 Terminal Accesso...

Страница 16: ...6 2 11 16 5 8 x 5 16 180 0057 Dodge Bushing Shaft Size Keyway Size Bushing Number Warner Electric Dodge 1 2 1 8 x 1 16 180 0101 1210 9 16 1 8 x 1 16 180 0102 5 8 3 16 x 3 32 180 0103 11 16 3 16 x 3 32...

Страница 17: ...Warner Electric 800 825 9050 P 209 WE 819 0517 17 NOTES...

Страница 18: ...anty lasts so the above limitation may not apply to you Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warn...