DIP Switch selection
+
1 2
3
4
5 6
7 8
OFF
ON
LOGIC CONTROL
DIP SWITCH
24VDC
+
-
DIP1
if ON PNP Logic control input
disabled
DIP2
if ON Full Wave
forcing
If ON, Over-excitation is always enabled.
DIP3
if ON Over-excitation
Disabled
50ms 100ms 150ms 500ms 1000ms
(Default)
1500ms 2000ms 3000ms 4000ms
DIP4
ON
ON
ON
ON
ON
ON
ON
DIP5
ON
ON
ON
ON
ON
DIP6
ON
ON
ON
ON
DIP7
ON
ON
ON
ON
ON
ON
DIP8
Not used
Examples
AC switching with external contactor
(not supplied)
/ 24VDC PNP Control not used / 1s Over-excitation:
DIP1
:
ON
DIP2
:
OFF
DIP3
:
OFF
DIP4:
ON
DIP5:
ON
DIP6:
OFF
DIP7:
ON
24VDC PNP Control Enabled / 500ms Over-excitation:
DIP1
:
OFF
DIP2
:
OFF
DIP3
:
OFF
DIP4:
ON
DIP5:
ON
DIP6:
ON
DIP7:
ON
AC switching with external contactor
(not supplied)
/ 24VDC PNP Control not used /
Full wave control (no Over-excitation):
DIP1
:
ON
DIP2
:
ON
DIP3
:
NA
DIP4:
NA
DIP5:
NA
DIP6:
NA
DIP7:
NA
AC switching with external contactor
(not supplied)
/ 24VDC PNP Control not used / Half wave control :
DIP1
:
ON
DIP2
:
OFF
DIP3
:
ON
DIP4:
NA
DIP5:
NA
DIP6:
NA
DIP7:
NA
Installation
1
DC BRAKE +
2
DC BRAKE -
3
SHUNT+
4
SHUNT-
5
DC
6
DC SWITCH -
7
AC
8
AC
9
PE
Brake
Measuring loop
- If not used, please Short Circuit 3 & 4 -
Fast Response time Switch OFF.
- If not used, please Short Circuit 5 & 6 -
Protective circuit
(FF 5 Amps)
Connected to the Grid
100 VAC to 500 VAC (+/- 10%)
50 – 60 Hz