4
Warner Electric • 800-825-9050
P-2100-WE • CBCx-001
Synoptic:
Technical Data
Input Voltage
100 VAC to 500 VAC (+/- 10%) 50 – 60 Hz
Output Voltage
90 VDC to 450 VDC
With Over-excitation
U
Brake
(VDC) = 0,9 x U
AC
(Limited to the selected over-excitation time)
Full Wave
U
Brake
(VDC) = 0,9 x U
AC
Half Wave (Holding voltage) U
Brake
(VDC) = 0,45 x U
AC
Max T °C
Output Current
70°C
2 Amps Over-excitation (double Wave) / 1 Amps Holding (Single Wave)
60°C
3 Amps Over-excitation (double Wave) / 1.5 Amps Holding (Single Wave)
50°C
5 Amps Over-excitation (double Wave) / 2.5 Amps Holding (Single Wave)
AC Input:
100 to 500 VAC
On/Off Switch
(AC Side)
Output
Voltage suppression
Over-Excitation
DIP4-7
: Programmable Over-Excitation Time:
50ms to 4000ms.
DIP3
: Diable
Full Wave
DIP2
: Enable
Bridge Rectifier
DC Switch OFF
Shunt
Logic Control
(PNP type)
DIP1: Disable
!
!