ELECTRICAL CONNECTIONS
Figure 11. Wiring Installation diagram
Blue
Black
Red
Yellow
Black
Red
Green
Splice and tape
wire together
Remote optional
SYSTEM CHECK
WARNING
To prevent serious injury or death:
Always spool the winch rope onto the drum
as indicated by the drum rotation label.
Always Wind Rope on Bottom of Drum.
Never Wind Rope Over Top of Drum.
Once you have performed system check.
Turn key switch to ON position and check
winch for proper operation. The rope should
spool in and out in the direction indicated on
the switch.
Check
Before fi rst
operation
After each
use
Every 90 days
Take time to fully read the Instructions
and/or Operations Guide, and/or Basic
Guide to Winching Techniques, in order to
understand your winch and its operations
X
Check fasteners and make sure they are
tight and to proper torque.
Replace damaged fasteners.
X
X
X
Verify wiring to all components is correct
and be certain that all connections are
tight.
X
X
Verify there is no exposed/bare wiring or
terminals.
Cover any exposures with terminal
boots, heat shrink tubing or electricians
tape.
X
X
Inspect rope for damage.
Replace rope immediately if damaged.
X
X
X
Keep winch, rope and switch control
free from contaminants.
Use a clean rag or towel to remove
any dirt and debris.
X
IN