TH115 A/F/AF
2013-01-10 2/2
The thermostat has 3 modes of operation.
Automatic Mode
The thermostat follows the programmed schedule. To place the
thermostat in this mode, press Mode/Ret until is displayed. The
data of the current schedule period are also displayed.
Temporary Bypass
If you modify the setpoint temperature (by pressing the
, or
button) when the thermostat is in automatic mode, the new
temperature will be used until the beginning of the next period.
flashes during the bypass. You can cancel the bypass by pressing
Mode/Ret.
Programmed Schedule
The schedule consists of 4 periods per day which represents a
typical week day. You can program the thermostat to skip the periods
that do not apply to your situation. For example, you can skip periods
2 and 3 for the weekend.
NOTE: If you wish to use only 2 periods, set the periods “1 and 4” or
periods “2 and 3”. Early Start will not work if you set periods “1 and 2”
or periods “3 and 4” .
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically
changes from Comfort ( ) temperature to Economy ( ) temperature.
You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.
To modify the schedule:
1) Press Pgm to access the programming mode. Period 1 is
selected.
2) Press Day to select the day to program (hold for 3 seconds to
select the entire week).
3) Press Hour and Min to set the start time of the selected period,
or press Clear if you want to skip the period (--:-- is displayed).
4) Press Pgm to select another period, or press Day to select
another day. Then repeat step 3.
5) Press Mode/Ret to exit the programming mode.
NOTE: If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.
Manual Mode
The programmed schedule is not used. The temperature must be set
manually. To place the thermostat in this mode:
1) Press Mode/Ret until is displayed.
2) Set the temperature using the
, or button.
Vacation Mode
In this mode, the thermostat uses the vacation preset temperature.
There are two ways to place the thermostat in Vacation mode:
• Press the button on the thermostat. When the Vacation mode is
activated this way, the icon appears on the screen without
flashing.
• From any remote control device (if connected at installation). When
the contact closes, the thermostat is placed in Vacation mode and
the icon flashes on the screen. All buttons on the thermostat are
locked. When the contact opens, the thermostat returns to the
preceding mode.
NOTE: When the Vacation mode is activated from a remote control
device, it can only be deactivated using the device
.
The measured temperature is below the thermostat’s display
range. Heating is activated.
The measured temperature is above the thermostat’s display
range. Heating is deactivated.
Verify the thermostat and sensor connections.
:
Supply: 208/240 VAC, 50/60 Hz
Maximum load: 15 A (resistive only)
Connection type: 4 wires, double pole
Display range: 0 °C to 70 °C
Ambient setpoint range (A/AF modes): 5 °C to 30 °C
Floor setpoint range (F mode): 5 °C to 40 °C
Floor limit range (AF mode): 5 °C to 40 °C
Display resolution: 0.5 °C
Operating temperature: 0 °C to 50 °C
Storage temperature: -20 °C to 50 °C
Heating cycle length: 15 minutes
Remote input: Dry contact
Size (H • W • D): 124 x 70 x 23 mm
Data backup: In the event of a power failure, most settings are saved. Only the
time must be re-adjusted if the power failure lasts more than 6 hours. The
thermostat will return to the mode that was active prior to the power failure.
Certifications:
WARMUP HEATING SYSTEMS NZ LTD
FIVE (5) YEAR WARRANTY
This product is warranted against defects in material and workmanship under
normal conditions of use for a period of five years from the date of purchase.
During this period, WARMUP will repair or replace the product, if it is defective
in normal operating conditions in terms of materials or workmanship, with a
new product of equivalent quality at WARMUP’s option.
The warranty does not cover costs of transportation, removal, installation or
damage caused by misuse or accident. In no event will WARMUP be liable for
consequential loss resulting from the installation of the product. Any defective
product should be sent with the original invoice to the original installer, or
shipped prepaid, insured and sent to the following address:
WARMUP New Zealand Ltd
Copsey Business Park
20 Copsey Place,
Avondale, Auckland.
Phone:
0800 WARMUP (927-687)
Email:
Website: www.warmup.co.nz
Modes of Operation
Period
Description
Associated temperature setting
Wake-up
Away from home
Return home
Sleep
Period Setting
MO
TU
WE
TH
FR
SA
SU
5:30
5:30
5:30
5:30
5:30
6:00
6:00
8:00
8:00
8:00
8:00
8:00
9:00
9:00
18:00 18:00 18:00 18:00 18:00 18:00 18:00
21:30 21:30 21:30 21:30 21:30 21:30 21:30
Error Messages