background image

TH115 A/F/AF

                          2013-01-10                    2/2

The thermostat has 3 modes of operation.

 Automatic Mode

The thermostat follows the programmed schedule. To place the 
thermostat in this mode, press Mode/Ret until   is displayed. The 
data of the current schedule period are also displayed.

Temporary Bypass

If you modify the setpoint temperature (by pressing the 

,   or   

button) when the thermostat is in automatic mode, the new 
temperature will be used until the beginning of the next period.   
flashes during the bypass. You can cancel the bypass by pressing 
Mode/Ret.

Programmed Schedule

The schedule consists of 4 periods per day which represents a 
typical week day. You can program the thermostat to skip the periods 
that do not apply to your situation. For example, you can skip periods 
2 and 3 for the weekend.

NOTE: If you wish to use only 2 periods, set the periods “1 and 4” or 
periods “2 and 3”. Early Start will not work if you set periods “1 and 2” 

or periods “3 and 4” .

The Comfort ( ) temperature is used in periods 1 and 3 and the 
Economy ( ) temperature is used in periods 2 and 4. For example, 
when the period changes from 1 to 2, the setpoint automatically 
changes from Comfort ( ) temperature to Economy ( ) temperature.
You can have a different program for each day of the week; i.e., each 
period can start at different time for each day of the week. The 
thermostat has been programmed with the following schedule.

To modify the schedule:
1) Press Pgm to access the programming mode. Period 1 is 

selected.

2) Press Day to select the day to program (hold for 3 seconds to 

select the entire week).

3) Press Hour and Min to set the start time of the selected period, 

or press Clear if you want to skip the period (--:-- is displayed).

4) Press Pgm to select another period, or press Day to select 

another day. Then repeat step 3.

5) Press Mode/Ret to exit the programming mode.

NOTE: If no button is pressed for 60 seconds, the thermostat will 
automatically exit the programming mode.

 Manual Mode

The programmed schedule is not used. The temperature must be set 
manually. To place the thermostat in this mode:
1) Press Mode/Ret until   is displayed.
2) Set the temperature using the 

,   or   button.

 Vacation Mode

In this mode, the thermostat uses the vacation preset temperature. 
There are two ways to place the thermostat in Vacation mode:
• Press the   button on the thermostat. When the Vacation mode is 

activated this way, the   icon appears on the screen without 
flashing.

• From any remote control device (if connected at installation). When 

the contact closes, the thermostat is placed in Vacation mode and 
the   icon flashes on the screen. All buttons on the thermostat are 
locked. When the contact opens, the thermostat returns to the 
preceding mode.

NOTE: When the Vacation mode is activated from a remote control 

device, it can only be deactivated using the device

.

The measured temperature is below the thermostat’s display 
range. Heating is activated.
The measured temperature is above the thermostat’s display 
range. Heating is deactivated.

Verify the thermostat and sensor connections.

:

Supply: 208/240 VAC, 50/60 Hz
Maximum load: 15 A (resistive only)
Connection type: 4 wires, double pole
Display range: 0 °C to 70 °C
Ambient setpoint range (A/AF modes): 5 °C to 30 °C
Floor setpoint range (F mode): 5 °C to 40 °C
Floor limit range (AF mode): 5 °C to 40 °C
Display resolution: 0.5 °C
Operating temperature: 0 °C to 50 °C
Storage temperature: -20 °C to 50 °C
Heating cycle length: 15 minutes
Remote input: Dry contact
Size  (H • W • D): 124 x 70 x 23 mm
Data backup: In the event of a power failure, most settings are saved. Only the 
time must be re-adjusted if the power failure lasts more than 6 hours. The 
thermostat will return to the mode that was active prior to the power failure.

Certifications: 

WARMUP HEATING SYSTEMS NZ LTD

FIVE (5) YEAR WARRANTY

This product is warranted against defects in material and workmanship under 
normal conditions of use for a period of five years from the date of purchase. 
During this period, WARMUP will repair or replace the product, if it is defective 
in normal operating conditions in terms of materials or workmanship, with a 
new product of equivalent quality at WARMUP’s option.
The warranty does not cover costs of transportation, removal, installation or 
damage caused by misuse or accident. In no event will WARMUP be liable for 
consequential loss resulting from the installation of the product. Any defective 
product should be sent with the original invoice to the original installer, or 
shipped prepaid, insured and sent to the following address:

WARMUP New Zealand Ltd
Copsey Business Park
20 Copsey Place,
Avondale, Auckland.

Phone:

0800 WARMUP (927-687)

Email:

[email protected]

Website: www.warmup.co.nz

Modes of Operation

Period

Description

Associated temperature setting

  

Wake-up

  

Away from home

  

Return home

  

Sleep

Period Setting

MO

TU

WE

TH

FR

SA

SU

  

5:30

5:30

5:30

5:30

5:30

6:00

6:00

  

8:00

8:00

8:00

8:00

8:00

9:00

9:00

  

18:00 18:00 18:00 18:00 18:00 18:00 18:00

  

21:30 21:30 21:30 21:30 21:30 21:30 21:30

Error Messages

Technical Specifications

Warranty

Customer Assistance

Отзывы: