background image

Installation Guide:

for the Warmup 

tempo

 Digital Programmable Thermostat

Part of the Element Series

 Introduction

The 

tempo

 thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup 

underfloor heating system. The thermostat is designed to receive temperature input signals from the following 

sensors:

1.  Air sensor located inside the thermostat

2. 

Floor sensor installed in the floor to be heated (see Warmup heater instructions for details)

The thermostat is not a safety device and should only be used with Warmup heating products. In order to avoid 

damaging your flooring the correct floor type must be selected during the thermostat programming process.

Electrical Specification

:

• 

Supply voltage: 230V +/-15% at 50Hz

•  Thermostat is not designed for use with intermittent power supply.

• 

Maximum Switch Load:  16A resistive

•  Insulation Class : II 

•  Housing : IP20

•  Sensor NTC : 10K @ 25°C

•  Standards:  EN60730-1 & EN60730-2-9

•  Meets LVD and EMC directives for safety and electromagnetic compatibility

WARNING – Important safety note

This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should 

always isolate the power supply before attempting to install or repair the 

tempo

 thermostat. The thermostat should 

not be put into operation unless you are certain that the entire heating installation complies with current general 

safety requirements for electrical installations. Electrical installation must be in accordance with the latest IEE Wiring 

Regulations and appropriate Statutory Regulations.

The thermostat should be installed inside a single gang electrical wall box that is at least 32mm deep. For optimal 

performance, the thermostat should be located in an area with good ventilation. It should not be installed beside a 

drafty window/door, in direct sunlight or above another heat generating device (e.g. Radiator or TV).

The thermostat is designed for operation between 0°C and 50°C with relative humidity less than 80%.

 Location and installation of floor sensor

The optimum location of the floor sensor is described in each Warmup heater installation manual. Refer to that manual 

when selecting floor sensor location.

Warmup recommend the use of conduit when installing the floor sensor. The conduit will protect the sensor and will 

allow easier repair of the sensor in the case of sensor damage after flooring has been laid.

 Installation:

Separate the front housing of thermostat from the wall module:

1.  Unscrew both closing screws (bottom of thermostat) until they will not turn any 

further.

2.  Release front housing by gripping the lower half of outer frame and pulling 

outwards then upwards.

3.  Place front housing somewhere safe.

4. 

Run all wires to the wall box. Check to ensure that you have included the 

following:

•  Power (Live and Neutral)

•  Heater (Live and Neutral)

•  Floor sensor

•  Fil pilote (France only)

5. 

Pull wires through the wall box and complete terminal wiring. 

IMPORTANT:

 Ensure that multi strand wires are fully inserted into the terminal and 

secured tightly. 

Any loose strands should be trimmed as they could cause a 

short-circuit.

If connecting more than two heaters, an electrical junction box will be required.

 

Thermostat location 

1

2

3

4

ELT-01-XX-01 - Installation guide V1.0 © Warmup plc - 2013

Содержание tempo

Страница 1: ...ogrammed operation this thermometer will show whether the thermostat is at Comfort or Setback temperature The icon will be displayed when Comfort 1 2 is the target temperature Only used with the Fil Pilote 3 This icon is displayed when the heating is on 4 These icons show the type of temperature regulation being used Floor Sensor Air Sensor Regulator This mode should only be used in special situat...

Страница 2: ...Getting started In order to program the tempo thermostat all you need to do is slide the Program Slide control from the top position to the bottom position customising the program along the way If you make a mistake return the Program Slide control to the previous position and start again In order to change a setting value turn the Rotary Control Pressing the Main Button will accept the value and ...

Страница 3: ...ld the Main Button for 3 seconds it will copy the start time to the next day Tip If you want to set the thermostat so that it is keeping the comfort temperature all day and only setback at night then just set the day start time equal to the evening start time Set Temperatures Here you can set the temperature which will be used for the comfort and setback temperatures Done Move the Program Slide co...

Страница 4: ...s you will automatically exit the installer setting mode Installer Step Setting Configured Default Value LCD Example 1 Change clock format 12hr 24hr 24 2 Change unit of measurement Degree C F C 3 Change sensor used to target temperature Floor Air Regulator Note In regulator mode the thermostat will run for a set number of minutes in a 10 minute cycle Floor 4 Set Floor Sensor Type If you already ha...

Страница 5: ...our heating is coming on too early then this may be because the Adaptive Learning function is turned on This function allows your thermostat to learn how long it will take to heat up to ensure it is the correct temperature at the start of the comfort periods See installer settings section of this guide Incorrect calibration Your thermostat should not need any calibration however if you would like ...

Страница 6: ...user Warmup s sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESSED OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON ...

Страница 7: ...d appropriate Statutory Regulations The thermostat should be installed inside a single gang electrical wall box that is at least 32mm deep For optimal performance the thermostat should be located in an area with good ventilation It should not be installed beside a drafty window door in direct sunlight or above another heat generating device e g Radiator or TV The thermostat is designed for operati...

Страница 8: ...unting holes and tighten 3 Ensure that thermostat is straight before tightening completely 4 Replace thermostat front housing 5 Ensure front housing is securely fixed 6 IMPORTANT Tighten both retaining screws Powering up You can now power up the thermostat and begin the programming process UK Warmup Plc 702 Tudor Estate Abbey Road London NW10 7UW T 0845 345 2288 International 44 208 453 6868 F 084...