Tiler Instructions 

This floor has been fitted with a Warmtech undertile heater. Please read the 

following  tips  to  ensure  safe  tiling  and  prevent  accidental  damage  to  the 

heater. 

 

(The  heating  element  is  a  double  insulated  multi-stranded  element  and  is 

designed to withstand normal tiling practices. We do ask that you take special 

care  to  ensure  its  integrity. 

Additional  care  should  be  taken  after  tiling 

when cleaning out between the tiles prior to grouting

. This is when you are 

most likely to cause damage to the heating element). 

 

The element is adhered to the floor with a combination of adhesive tape and 

concentrated  latex  (SBR  type)  adhesive.  The  floor  must  not  be  walked  over 

until  the  adhesive  has  dried  clear  (24  hours  depending  upon  the  ambient 

room temperature). 

 

With care you can tile directly over the element. We have found that using a 

thin bed application method with a 10mm-12mm notched trowel works best. 

It  is  recommended  that  all  elements  are  covered  with  a  leveling  screed  or 

diluted  mix  of  the  tile  adhesive  to  be  used  –  to  ease  tile  installation  and 

further  reduce  the  chance  of  accidental  damage.  Either  way  a  flexible 

adhesive  must  be  used.  Latex  modified  (acrylic,  PVA,  SBR)  cement  based 

grout should be used with at least a 10% “by weight of solids based” content 

of latex. 

 

If  waterproofing  is  required  but  has  not  been  installed  prior  to  the  heating 

installation, it may be possible to waterproof over the heating elements.  

Confirmation  regarding  its  acceptability  to  be  installed  over  the  heating 

should be obtained from the waterproofing supplier. 

 

 

 

 

 

 

 

 

 20 

Содержание underfloor heating

Страница 1: ...on Manual For undertile heating element Please read the ENTIRE Installation Manual before attempting to do the installation Incorrect installation could damage the cable and therefore make your warran...

Страница 2: ...armtech Heating Systems accepts no liability expressed or implied for any loss or consequential damage suffered as a result of installations which in any way contravene the instructions that follow If...

Страница 3: ...suitability of the sub floor to be heated check with your local tile shop tiler or call the Warmtech technical helpline DON T cut or attempt to shorten the element wire at any time DON T commence ins...

Страница 4: ...Simple Steps to Luxurious Warmth 4...

Страница 5: ...h end It must not be cut shortened or lengthened Once the heater has been installed avoid all traffic over the heating element until the floor has been tiled If the floor is not being tiled immediatel...

Страница 6: ...000 25 ohms 166 5m 9 37 13 19 15 46 211 150 128 UT2500 21 ohms 208 5m 11 85 16 69 19 56 214 152 129 UT3000 16 ohms 250 0m 14 31 20 14 23 61 210 149 127 Sizing Guide For larger or different area sizing...

Страница 7: ...configuration there are many instances where departure from this configuration may be desirable Below are a few drawings illustrating such instances In each of the above examples the floor space is h...

Страница 8: ...Pre wiring of Electrical Installation Wall mounted thermostat 8...

Страница 9: ...eated and tiled it is strongly recommended that a fibre cement sheet is installed prior to heating and tiling Waterproofing if required or movement control joints should be done prior to the installat...

Страница 10: ...element on the floor Helpful Hints The element is a continuous wire that must not be shortened or lengthened Even spacing of the wire will ensure an even temperature of your tiles The adhesive spray e...

Страница 11: ...flat floor surface it will be necessary to chisel out or chase short channels in the sub floor at the start point see steps 4 and 5 and the end point This minimises the increased height presented by...

Страница 12: ...observing the perimeter distances and join the corners up to form a marked out perimeter Mark up the spacing intervals for the element wire following the sizing guide plus your actual calculation The...

Страница 13: ...n at each corner The element wire should run from the start point in a U shape to the furthest corner from the start point Once the element wire has been laid out around the perimeter start laying out...

Страница 14: ...ured element should be laid out in reverse order i e starting from the end point and working backwards to the last point at which the element was taped down In order to achieve even coverage of the ba...

Страница 15: ...int these will need to be carefully pulled up within the wall cavity using the draw wire If the standard controller has been upgraded to include a floor sensing probe the floor sensing probe must be i...

Страница 16: ...the heating elements for ease of tiling Allow 24 48 hours before commencing tiling Check the resistance on the heater using a multi meter and confirm the reading against factory specifications label...

Страница 17: ...to the ON position and ensure that the audible alarm sounds If the alarm sound cannot be heard please call 1300 138 126 for technical assistance Turn to the OFF position during connection to the heati...

Страница 18: ...sitioned incorrectly care should be taken not to damage the heating element when lifting the tile Do not store or cut tiles on top of the heater Do not allow chippings or dust to contaminate the floor...

Страница 19: ...electrical connections including the connection of the controller must be undertaken by a licensed electrician Means shall be provided to ensure all pole disconnection from supply Ensure all electric...

Страница 20: ...til the adhesive has dried clear 24 hours depending upon the ambient room temperature With care you can tile directly over the element We have found that using a thin bed application method with a 10m...

Страница 21: ...eating elements Wearing inappropriate footwear soft soled shoes or socks are ideal Lifting of misplaced or damaged tiles Removing excess adhesive from between tiles by scraping between them Removing p...

Страница 22: ...lfunctioning of the heating within the two 2 year warranty period as a result of a manufacturing defect Warmtech or it s Distributors reserve the right to charge for any repairs faults tracing caused...

Отзывы: