48
◆
the match between the pump body and pump core
The four pump blades were set in the four grooves of the pump core
,
which move centrifugally
clockwise in the pump
,
the cooperation gap between the pump enclosure and the pump core should
be kept in 06~0.08mm
,
to ensure that the air pump can produce sufficient pressure.
A
.
pump body
B . gap 0.06~0.08mm
C
.
pump core
D
.
screw
E
.
pump blade
◆
fixation of the fan blades
Install fan blade on motor shaft und use set screw to tighten them firmly
A
.
fan blade
B
.
motor shaft
C
.
set screw
WIRING DIAGRAM