7 October 2021
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
………….
Copyright ©
7
BLOCK ALCOVE & TRIM OUT DETAILS
Note:
Centre Line of Flue is `NOT’ in
Centre of the Chimney Chase
MINIMUM HEAT CELL BLOCK ALCOVE CLEARANCES
Firebox
SG / EG
700
SG / EG
780
SG / EG
900
SG / EG
1100
SG / EG
600
Heat cell Clearance Width
OO
810
1210
1210
1210
690
Alcove Clearance Height
PP
2400
2400
2400
2400
2400
Alcove Clearance Depth
600
600
600
600
600
Window Height
VV
630
630
630
630
630
Window Width
WW
800
880
1000
1200
700
Chimney Chase Clearance
TT
350
350
400
400
300
Cool Air exter-
nal Intake Vent
2x 100mm
Warm Air Vent
2x 100mm
Warm Air Vent
2x 100mm
Cool Air exter-
nal Intake Vent
2x 100mm
Note:
Ensure that the Fire and Flue System is Installed before
the alcove access is blocked off.
Block modules may vary to the drawing. (See Blocklayer)