801 Glasgow Ave.
Fort Wayne, IN 46803
MODEL
HS OIL
BURNERS
Publication Date 8/01/01
Revision 12
Manual 21663
U.S. Patent No. 4,388,064
ELECTRIC SHOCK HAZARD
OVERHEATING HAZARD
NEVER ATTEMPT TO USE
GASOLINE AS A FUEL FOR THIS
BURNER, AS IT IS MORE COMBUSTIBLE AND COULD
RESULT IN A SERIOUS EXPLOSION.
HIGH VOLTAGES ARE PRESENT IN THIS
EQUIPMENT. FOLLOW THESE RULES TO
AVOID ELECTRIC SHOCK.
Use only a properly grounded circuit. A ground
fault interrupter is recommended.
Do not spray water directly on burner.
Turn off power before servicing.
Read the owner’s manual before using.
SHOULD OVERHEATING OCCUR:
Shut off the manual oil valve to the appliance.
Do not shut off the control switch to the pump or blower.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
SPECIFICATIONS
FUELS
Use No. 1 or No. 2 heating oil (ASTM D-396) only.
* NEVER burn garbage or refuse in the heating unit.
* NEVER try to ignite oil by tossing burning paper or other material into the heating unit
* NEVER burn waste or crankcase oil in the heating unit.
ELECTRICAL
Power Supply.........................115V / 60HZ / 1 PH
Motor......................................3450 RPM, N.E.M.A. Flange, Manual Reset Overload Protection
Ignition ...................................10,000V / 23MA secondary, Continuous Duty-Shielded Interrupted
FIRING CAPACITIES - MODEL HS
0.50 TO 3.00 GALLONS PER HOUR
- See page 6.
70,000 TO 420,000 BTU/HR INPUT
FUEL UNIT
Suntec or Danfoss
DIMENSIONS (STANDARD)
HEIGHT ......................................................12 1/2”
WIDTH........................................................12 7/8”
DEPTH .........................................................7 3/4”
CENTER LINE
OF TUBE TO FLOOR.........................................7”
MOUNTING
Rigid Flange, Adjustable Flange, or Base Mount
INSTALLATION OF BURNER
INSTALLATION OF THE BURNER MUST BE DONE BY A QUALIFIED INSTALLER IN ACCORDANCE WITH REGULATIONS OF THE NATION-
AL FIRE PROTECTION STANDARD FOR OIL-BURNING EQUIPMENT, NFPA NO. 31, AND IN COMPLETE ACCORDANCE WITH ALL LOCAL
CODES AND AUTHORITIES HAVING JURISDICTION.
A QUALIFIED INSTALLER IS THE PERSON WHO IS RESPONSIBLE FOR THE INSTALLATION AND ADJUSTMENT OF THE EQUIPMENT
AND WHO IS LICENSED TO INSTALL OIL-BURNING EQUIPMENT IN ACCORDANCE WITH ALL CODES AND ORDINANCES.
THESE INSTRUCTIONS SHOULD BE AFFIXED TO THE BURNER
OR ADJACENT TO THE HEATING APPLIANCE.
Содержание HS
Страница 8: ...8 Notes...
Страница 9: ...9 Notes...