![Warming Trends CROSSFIRE CFB60 NG Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/warming-trends/crossfire-cfb60-ng/crossfire-cfb60-ng_owners-manual-and-instruction-manual_3528267026.webp)
www.Warming-Trends.com | 303 346 2224 | [email protected]
26
REPLACEMENT PARTS
PBIK
Push Button Ignition Kit: spark igniter rod and wire + push button battery operated control module
PB-SI
Spark igniter rod and wire
PB-CM
Push button battery operated control module
MBR
Mounting Bracket
3VIK-NG / 3VIK-LP
3V Ignition System
3VCM
3V Control Module
3VPA-NG / 3VPA-LP
3V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage)
3VGV-NG / 3VGV-LP
3V 120K BTU Capacity Gas Valve
3VBP
3V Battery Pack
24VIKHC-NG / 24VIKHC-LP
Standard 24V Ignition System (High Capacity)
24VGVHC-NG / 24VGVHC-LP
24V 400K BTU Capacity Gas Valve (High Capacity)
24VCM
24V Control Module for use with Standard Ignition Systems (HC)
24VPA-NG / 24VPA-LP
24V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage) for use with Standard Ignition Systems (HC)
24VT
9ROW7UDQVIRUPHUIRUXVHZLWKDOO9ROW,JQLWLRQ6\VWHPRW6XUIDFH,JQLWLRQV
P24VIKSC-NG / P24VIKSC-LP
Premium 24V Ignition System (Standard Capacity)
P24VCBSC
Premium 24V 290K BTU Capacity Control Box (Standard Capacity)
P24VIKHC-NG / P24VIKHC-LP
Premium 24V Ignition System (High Capacity)
P24VCBHC
Premium 24V 512K BTU Capacity Control Box (High Capacity)
P24VIKPA-NG / P24VIKPA-LP
3UHPLXP93LORW$VVHPEO\SLORWWXEHLJQLWHUVSDUNZLUHLJQLWHUEUDFNHWZLQGFDJHIRUXVHZLWK3UHPLXP,JQLWLRQ6\VWHPV6& +&
P24VIKWC
Wind Cage
FLKV12
½” Flex Line and Key Valve. For use with any burner up to 120K BTU’s. Kit Includes: (1) 36” L x ½” Diameter Flex Line + ½” Key Valve + 3” and 12” Key
FLKV34
¾” Flex Line and Key Valve. For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x ¾” Diameter Flex Line + ¾” Key Valve + 3” and 12” Key
FLKV34FIT180
¾” Flex Line, Key Valve, and FIT180. For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x ¾” Diameter Flex Line + ¾” Key Valve + 3” and 12” Key + ½” x
2” Nipple to connect threaded inside ¾” Flex Line Flare Connector to ½” Plate Coupling
DFLKV34
2x ¾” Flex Lines and Key Valve. For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x ¾” Diameter Flex Lines with + ¾” Key Valve + 3” and 12” Key
DFLKV34FIT250
2x ¾” Flex Lines, Key Valve, and FIT250. For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x ¾” Diameter Flex Lines + ¾” Key Valve + 3” and 12” Key +
(1) ¾” x ½” MM Reducer Fitting and (1) ¾” Tee for connection at ½” Plate Co (1) ¾” x 3” Nipple and (1) ¾” Tee for Key Valve connection
DFLKV34FIT300
2x ¾” Flex Lines, Key Valve, and FIT300. For use with any 300K+ BTU Burner. Kit Includes: (2) 36” L x ¾” Diameter Flex Lines + ¾” Key Valve + 3” and 12” Key + (1) ¾”
x 3” Nipple and (1) ¾” Tee for connection at ¾” Plate Co (1) ¾” Tee for Key Valve connection
FIT180
)OH[/LQH .H\9DOYH&RQQHFWLRQ)LWWLQJIRUXVHZLWKDQ\EXUQHURYHU.%78ōV.LWLQFOXGHVŐ[Ő1LSSOH&RQQHFWVŐ3ODWH&RXSOLQJWRLQVLGHWKUHDGHGŐ
Flex Line Flare Connector
FIT250
)OH[/LQH .H\9DOYH&RQQHFWLRQ)LWWLQJVIRU..%78%XUQHU.LWLQFOXGHVŐ[Ő005HGXFHU)LWWLQJDQGŐ7HHIRUFRQQHFWLRQDWŐ3ODWH
Co (1) ¾” x 3” Nipple and (1) ¾” Tee for Key Valve connection. Connects ½” Plate Coupling to two ¾” Flex Lines + connection of two ¾” Flex Lines to ¾”
Key Valve.
FIT300
)OH[/LQH .H\9DOYH&RQQHFWLRQ)LWWLQJVIRUN%78%XUQHU.LWLQFOXGHVŐ[Ő1LSSOHDQGŐ7HHIRUFRQQHFWLRQDWŐ3ODWH&RXSOLQJŐ[Ő
Nipple and (1) ¾” Tee for Key Valve connection. Connects ¾” Plate Coupling to two ¾” Flex Lines and two ¾” Flex Lines to ¾” Key Valve.
FL3612
36” L x ½” Diameter Flex Line (MM)
KV12
½” Key Valve + 3” Key
KEY3
3” Key
DRIPLEG12
½” Drip Leg Kit
LPRH
/35HJXODWRUPRXQWHGRQuŝƇ
” 10’ Hose with handwheel quick connect. For use up to 125k BTU’s. For use with a 20LB propane tank
LPHOSE10
/3uŝƇ
” 10’ Hose. For use with a 20LB Propane Tank
REGNG125
Regulator: 1/2” FNPT Inlet x ½” FNPT For use up to 125K BTU’s - Natural Gas
REGLP140
5HJXODWRUŐ)137,QOHW[uŝŐ)1372XWOHW)RUXVHXSWR.%78ōV/LTXLG3URSDQH
FPVK
Fire Pit Vent Kit: (2) 5.75” x 11.5” Vents + 18 square inches of vent area per vent
FL3634
36” L x ¾” Diameter Flex Line (MM)
KV34
¾” Key Valve + 3” Key
KEY24
24” Key
DRIPLEG34
¾” Drip Leg Kit
KEY12
12” Key
P24VIKCGPA-NG/ P24VIKCGPA-LP
24 Volt Hot Surface Ignition Pilot Assembly (Dual Pilot Tubes + I Igniter B Wind Cage) for use with Hot Surface Igni-
WLRQ6\VWHPV6WLJK&DSDFLW\
P24VCBSCCG
24 Volt Hot Surface Ignition 290K BTU Standard Capacity Control Box with Dual Pilot Connections
P24VCBHCCG
Premium 24 Volt 512K BTU High Capacity Control Box with Dual Pilot Connections