Warmhaus RecoWa Скачать руководство пользователя страница 11

11

warmhaus.com

Figure 8. 

Combi Boiler Control Unit Main Board Connections

Figure 9. 

Installing Batteries into the Room 

Thermostat Unit

7.4.3. Installation of the Room Thermostat 

Unit and Installing the Batteries

Open the battery compartment cover on 
the back of the Room Thermostat Unit, 
insert two 1.5V AA Alkaline batteries 
into the battery compartment, paying 
attention to the + and - poles, and close 
the lid. When the batteries are inserted 
for the first time, the backlight turns on 
and all symbols appear for a short time. 
The ambient temperature will then appear 
on the display and it will automatically 
connect to the Combi Control Unit/RF 
MODULE.

When the Room Thermostat Unit is 

MAINBOARD SCHEMATICS OF

THE RECOWA COMBI CONTROL

1) Thermostat control switch (Enabled / Disabled)

2) On/Off control communication cable (Brown)
3) OpenTherm combi boiler communication cable (Red)
4) Power cable (230V AC ~50Hz )
5) Transformer (230V AC to 6V AC)

6)    Factory reset button
7)    RF antenna
8)    LED light
9)    Relay

1

Combi

Boiler

2

3

4

5

6

8

7

9

RED

BROWN

POWER CABLE

(230V AC 50Hz)

Alkaline Battery

(2 x 1,5V DC)

Battery

Compartment

Cover

connected to the RF MODULE, the signal 
symbol 

  will appear on the screen. The 

Room Thermostat Unit is now ready for 
use. You can adjust the room temperature 
using the + and – buttons on the unit. 

For the proper and efficient operation of the room thermostat, please use 
alkaline batteries. Never use rechargeable batteries. It has a special protection 
measure against the reverse installation of the batteries.

Содержание RecoWa

Страница 1: ...WI FI SMART ROOM THERMOSTAT SET Installation Guide and User Manual warmhaus com...

Страница 2: ...m Thermostat Unit and Installing the Batteries 11 7 4 4 Extending the Battery Life 12 7 4 5 Tabletop Use of the Room Thermostat Unit 12 7 4 6 Installation of Room Thermostat Unit on the Wall 13 7 5 FE...

Страница 3: ...Weekly heating schedule 8 different heating time zones can be set with a precision of 0 1 degree for each day of the week 56 schedules in total The boiler failure codes can be read The Recowa Wi Fi Sm...

Страница 4: ...of the Smart Thermostat with remote control and should be kept for future reference After unpacking the device check whether the Smart Thermostat Set is complete If you have any doubt how to use it co...

Страница 5: ...This device is for indoor use only 9 Before inserting the batteries check that the contacts in the device and on the batteries are clean is necessary clean them Note the polarity when inserting the ba...

Страница 6: ...rms both the temperature and life into comfort 6 GENERAL FEATURES It is a Wi Fi Smart Room Thermostat Set with internet access that allows you to set the desired temperature from anywhere anytime usin...

Страница 7: ...trol Unit 3 Wall Mounting Bracket 4 2xAA Alkaline Battery 5 Power Supply Cable with Plug 6 Data Communication Cable OT ON OFF 7 Installation User Manual 8 Screw 9 Fixing plug Figure 1 Contents of Reco...

Страница 8: ...onnects to the Wi Fi network at home It has the following features It operates using a 220 V AC supply Thanks to the universal OpenTherm protocol it operates with all Warmhaus combi boilers that confo...

Страница 9: ...iler is included in the package First turn off your combi boiler and the electrical power fuse plug socket etc to which your combi boiler is connected To access the connection points before connecting...

Страница 10: ...ctions have been completed Before connecting to the combi boiler check 2 x Red OpenTherm communication cables in the 4 x 0 35 mm2 cross section four core cable as shown in the connection schematics Co...

Страница 11: ...the Room Thermostat Unit is MAINBOARD SCHEMATICS OF THE RECOWA COMBI CONTROL 1 Thermostat control switch Enabled Disabled 2 On Off control communication cable Brown 3 OpenTherm combi boiler communica...

Страница 12: ...communicate with the Combi Control Unit It shall not be placed on the places that receive direct sunlight that are near the radiators heat generating electronic devices and near the doors and windows...

Страница 13: ...he package Insert the Room Thermostat into the Wall Mount by matching the latches and pressing it gently make sure that the support leg is fully closed The Room Thermostat Unit is now ready for use Yo...

Страница 14: ...ation Temperature Adjustment Button Battery Level Symbol Temperature Unit Symbol C F Temperature value error code display Temperature Adjustment Button Failure Error symbol RF signal Digital Clock str...

Страница 15: ...e preset time 1 min 5 min 10 min 30 min This setting can only be changed by the authorized service Selecting a shorter time interval may cause the battery to run out more quickly but this will allow t...

Страница 16: ...and holding one of the keys it increases rapidly by an interval of 0 1 degree then rapidly by an interval of 0 5 degree After reaching the desired temperature if you do not press the buttons the set t...

Страница 17: ...chedule and time can be used b No Internet OFF Weekly schedule and time cannot be used Figure 17 Room Thermostat Unit Operation Operating Mode Abbreviations Wt Winter Heating and Domestic Hot Water ar...

Страница 18: ...paper clip or needle To do this unplug the Recowa Combi Boiler Control Unit from the mains Press the tip of a straightened paper clip towards the Restore Factory Settings Button through the hole on t...

Страница 19: ...Figure 20 2 Disconnect the power supply to the boiler if it is a plug in connection remove the plug from the socket and wait 5 seconds and insert the plug to the socket again If the power supply of y...

Страница 20: ...e ability of scheduling for a week on the scale of hours and minutes Modulated operation based on the room temperature CH circuit water pressure Return water temperature Combi boiler failure error cod...

Страница 21: ...ue you set independent from the schedule time Usually it allows you to keep the temperature at home at a constant room temperature value no matter it is day night time or comfort economy mode The reco...

Страница 22: ...mperature O C 40 C O C 40 C Storage Temperature O C 50 C O C 50 C INGRESS PROTECTION IP RATING 20 21 Precision of Temperature Measurement 0 1 C 0 1 C Precision of Setting Temperature 0 1 C 0 1 C Preci...

Страница 23: ...these rights your Recowa is repaired by our authorized service without any charge for labor costs replacement parts or any other charges The technical methods to be applied for the elimination of the...

Страница 24: ...ctive R TTE 1999 5 EC SAFETY Low Voltage Directive 2006 95 AT LVD EN 60950 1 2006 A2 2013 ELECTROMAGNETIC COMPATIBILITY Electromagnetic Compatibility Directive 2004 108 AT EMC EN 301 489 1 3 17 V1 9 2...

Страница 25: ...25 warmhaus com...

Страница 26: ...26 warmhaus com...

Страница 27: ...ve been prepared meticulously but our right to make changes and improvements in our products that may affect the accuracy of the information contained in this brochure booklet is reserved All products...

Страница 28: ...WARMHAUS Is tma ve So utma Sistemleri San Tic A I ktepe OSB Mah Park Cad No 10 16140 Nil fer BURSA T 90 224 295 94 00 F 90 224 411 23 77 www warmhaus com tr info warmhaus com 150 11 606 000064 Revisio...

Отзывы: