background image

4

VERTICAL ASSEMBLAGE OF RADIATORS:

 

  Radiators should be carried and assembled  

without being unpacked. The unpacked 

radiators must not be carried by being hold 

by custards aside.

3.  The stocking must be made in a ventilated 

and dry place without unpacking radiators.

4.  In the course of stocking, radiators must 

     be stacked by no more than 10 pieces.

5.  The maximum functioning pressure of 

radiators is 10 Bars. 

6.  Radiators are delivered with assemblage 

accessories: 3 stoppers, 1 drain and fixing 

pins with ankles and screw factories. These 

accessories must have to be assembled in 

accordance with the figure 1. The fixing pins 

must be fixed in order to guarantee stability 

and to support the weight of the filled 

radiator.

a) The Warmhaus Radiators have to be 

assembled by using the delivered fixing pins 

(see it in the Figure 1). 

b) The position of the fixing pins in comparison 

with the radiator is noted in the Figure 1.  The 

minimal distance between radiator and floor 

should not be less than 100 mm.

c)  Having drawn on the wall, the position of the 

fixing pins and of installed plugs, to take up 

the lower pins of the radiator. Assembly 

then, the top hanger brackets without 

tightening the screws.

7.  The warranty period is 10 years from the 

date of delivery.

ATTENTION THE POSITION OF THE LEGS OF 

FIXING MUST RESPECT COAST B OF THE FACE 

1 THERE.

d) After positioning of the radiator, tighten the 

top hanger brackets.

e) Assembly the stoppers after the chosen 

assemblage chosen as well as the air vent 

plugs which will be imperatively on the 

upper part of the radiator.

f)  Connect the feeding of the installation by 

taking care to allow these ones to dilate 

without putting pressure on the radiator.

ATTENTION !

•  This product is only conceived to be used a 

system of central heating  or a system of hot 

water tank of central heating, with a purpose 

to guarantee a residential heating or an 

individual heating.

•  The assemblage of this product must be made 

by a competent skilled person in this activity.

•  Control if the radiator which you received is a 

good model and, if it has good dimensions 

before unpacking.

•  Do not throw the packing before having 

proved that the small packet containing the 

linking and assemblage rooms is in your 

possession. 

•  We recommend you to take personal security 

measures in the course of radiator 

assemblage.

The necessary specifications of the water used in 

a radiator have to be:

a) pH: minimum 9,5 - maximum 11,5

b) Complete hardness: maximum 30 ppm 

CACO3

c)  An oil dumping device must be set up on 

heating circuit to have no air and oxygen 

presence in the radiator.

Hardness of the water used in the circuit of a 

central heating should not be higher than 

aforementioned value. If the hardness of the 

used water is higher than aforementioned value 

a corrective action or a treatment will have to be 

set up.

The deterioration of the radiator due to 

different problems of water cancels 

the guarantee.

1.  Do not unpack radiators in the course of 

construction work or renovation and as long 

as painting, coating or other jobs are finished. 

You can take radiators up, if necessary, 

without unpacking them. 

2.  Pay attention to the fact that the products are 

not thrown on the facedown, in the course of 

manipulation and assemblage. 

Содержание Flat

Страница 1: ...VERTICALPANEL RADIATORINSTALLATION ANDOPERATION MANUAL...

Страница 2: ...2 Vertical Flat Panel Standart Standard Type De Ligne Line Type Plate Flat...

Страница 3: ...ccording to the TS 442 standard in a production plant respecting the quality assurance system and certified TSE ISO EN 9001 2008 TSE ISO EN 14001 2004 TSE EN 442 GOST R UKR SERPO DIN EN 442 NF Mark NF...

Страница 4: ...eratively on the upper part of the radiator f Connect the feeding of the installation by taking care to allow these ones to dilate without putting pressure on the radiator ATTENTION This product is on...

Страница 5: ...ust not be tightened in an excessive way A B 1 300 400 60 2 500 600 90 3 700 750 130 4 900 180 C D E F 1 1400 40 1305 55 2 1500 40 1405 55 3 1600 40 1505 55 4 1800 40 1705 55 5 2000 40 1905 55 6 2200...

Страница 6: ...h notice Any faulty assemblage any damage and dysfunctions emerging from a faulty installation Any damage and any dysfunctions dysfunctions resulting from a load transport emptying stocking and assemb...

Страница 7: ...s information and approval Any dysfunctions caused by a maintenance or repair made by none permitted persons Any deterioration and other damages caused by any long term stocking in a construction sit...

Страница 8: ...N MANUAL Nil fer Organize Sanayi B lgesi Selvi Cadde No 3 16140 BURSA T RK YE T 90 224 295 94 00 F 90 224 411 23 77 www warmhaus com BLYSS T20 Vertical Panel Radiator Installation Operation Manual Cod...

Отзывы: