Warmhaus Enerwa Plus 2530 Скачать руководство пользователя страница 20

Enerw

a Plus C

ombi User Manual-(UK) C

ode : 150

.11

.606.

000

123

R

evision Da

te: 06.

20

21

ENERWA PLUS

FOR ANY TECHNICAL QUERIES PLEASE RING THE 

WARMHAUS CONSUMER / INSTALLER / TECHNICAL HELPLINE: 

0207 1646233

Enquiries about assets

If you have any questions about 

our power cables, gas lines, or 

other assets, please contact 

Cadent's Plant Protection 

team. Cadent provide first-line 

support for our assets. 

Gas Emergencies

If you smell gas or have 

accidentally hit the NTS pipeline 
please call us urgently:

0800 111 999

Electricity Emergencies

If you spot a potential hazard on 

or near an overhead electricity line 
please call us urgently:

0800 40 40 90

C

ONDENSING C

OMBI BOILERS

USER MANU

AL

NOTES FOR THE USER & INSTALLER

· 

0800 688 588

 

· [email protected] 

·  https://www.nationalgrid.com/uk/contact-us  

NATIONAL GRID UK EMERGENCY NUMBERS

Содержание Enerwa Plus 2530

Страница 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS...

Страница 2: ...cluding children with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safet...

Страница 3: ...of On Off Stand by and Summer Winter Modes 8 2 1 3 On Off Stand by Positions 8 2 1 4 Operation in Winter Mode 8 2 1 5 Operation in Summer Mode 9 2 1 6 Shutting off the Boiler 9 2 2 USE WITH ROOM THERM...

Страница 4: ...le The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installation errors shall be performed as free of charge without claimi...

Страница 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT S...

Страница 6: ...ly at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make any intervention...

Страница 7: ...s in this booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate...

Страница 8: ...ment change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is...

Страница 9: ...een on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON...

Страница 10: ...ice installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room therm...

Страница 11: ...tor systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1...

Страница 12: ...ler and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for auth...

Страница 13: ...mmunication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be r...

Страница 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Ga...

Страница 15: ...ectrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blocka...

Страница 16: ...and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat l...

Страница 17: ...relevant European directives Differences to product information listed elsewhere may result in different test conditions Only the data that is contained in this product information is applicable and...

Страница 18: ...ion Qfuel kWh 14 809 23 152 23 615 23 078 29 317 Annual fuel consumption AFC GJ 11 18 18 18 23 Condensing boiler Yes Yes Yes Yes Yes Low temperature boiler Yes Yes Yes Yes Yes Combi Boilernation boile...

Страница 19: ...19 warmhaus co uk...

Страница 20: ...dent s Plant Protection team Cadent provide first line support for our assets Gas Emergencies If you smell gas or have accidentally hit the NTS pipeline please call us urgently 0800 111 999 Electricit...

Отзывы: