Product FICHE & ErP Data

ErP Data

Manufacturer

Type-model / Technical data

Enerwa Plus boilers

Mark (s) of conformity

granted

Warmhaus

ErP & Product Fiche for Warmhaus boilers has been tested and reported on SZU Test / BRNO given bellow;

PRODUCT FICHE   (according to EU regulation No 811/2013 and 814/2013)

Enerwa Plus 24

Enerwa Plus 24

Enerwa Plus 28

Enerwa Plus 33

Enerwa Plus 33

2530 C

2530 C

3035 C

3540 C

3540 C

Space heating - Temperature application

High / Medium / 

Low

High / Medium 

/ Low

High / Medium 

/ Low

High / Medium / Low

High / Medium 

/ Low

Water heating - Declared load profile

L

XL

XL

XL

XXL

Seasonal space heating energy efficiency class

A

A

A

A

A

Water heating energy efficiency class

A

A

A

A

B

Rated heat output (Prated or Psup)

kW

24

24

28

33

33

Space heating - annual energy consumption

Q

HE

GJ

42,14

42,14

48,77

54,78

54,78

Water heating - Annual energy consumption

kWh (*)

26

37

34

39

42

GJ (**)

11

18

18

18

23

Seasonal space heating energy efficiency 

%

92

92

92

92

92

Water heating energy efficiency 

%

81

84

83

84

82

Sound power level LWA indoors

dB

52

52

54

50

50

Option to only operate during low demand periods

-

-

-

-

-

-

Specific precautions for assembly, installation 

and maintenance

Before any assembly, installation or maintenance the user and installation manual has to be read 

attentively and to be followed

All the data that is included in the product information was determined by applying the spesifications of the relevant European directives. Differences to product information 

listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid.

(*) Electricity   

(**) Fuel

HANDING OVER

After completing the installation and commissioning of the system the installer should hand over to the householder by the following actions:
1. Make the householder aware that the user instructions are located in the pocket in the drop down door and explain his/her responsibilities under the relevant 

national regulations.

2. Explain and demonstrate the lighting and shutting down procedures.
3. The operation of the boiler and the use and adjustment of all system controls should be fully explained to the householder, to ensure the greatest possible 

fuel economy consistent with the household requirements of both heating and hot water consumption. Advise the User of the precautions necessary to 
prevent damage to the system and to the building, in the event of the system remaining inoperative during frosty conditions.

4. Explain the function and the use of the boiler heating and domestic hot water controls.
Explain that due to system variations and seasonal temperature fluctuations DHW flow rates/temperature rise will vary, requiring adjustment at the draw 
off tap. It is therefore necessary to draw the users attention to the section in the Users Instructions titled “Control of Water Temperature” and the following 
statement: “Additionally, the temperature can be controlled by the user via the draw-off tap: the lower the rate the higher the temperature, and vice versa”.

Содержание Enerwa Plus 2530

Страница 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS...

Страница 2: ...cluding children with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safet...

Страница 3: ...of On Off Stand by and Summer Winter Modes 8 2 1 3 On Off Stand by Positions 8 2 1 4 Operation in Winter Mode 8 2 1 5 Operation in Summer Mode 9 2 1 6 Shutting off the Boiler 9 2 2 USE WITH ROOM THERM...

Страница 4: ...le The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installation errors shall be performed as free of charge without claimi...

Страница 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT S...

Страница 6: ...ly at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make any intervention...

Страница 7: ...s in this booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate...

Страница 8: ...ment change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is...

Страница 9: ...een on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON...

Страница 10: ...ice installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room therm...

Страница 11: ...tor systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1...

Страница 12: ...ler and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for auth...

Страница 13: ...mmunication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be r...

Страница 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Ga...

Страница 15: ...ectrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blocka...

Страница 16: ...and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat l...

Страница 17: ...relevant European directives Differences to product information listed elsewhere may result in different test conditions Only the data that is contained in this product information is applicable and...

Страница 18: ...ion Qfuel kWh 14 809 23 152 23 615 23 078 29 317 Annual fuel consumption AFC GJ 11 18 18 18 23 Condensing boiler Yes Yes Yes Yes Yes Low temperature boiler Yes Yes Yes Yes Yes Combi Boilernation boile...

Страница 19: ...19 warmhaus co uk...

Страница 20: ...dent s Plant Protection team Cadent provide first line support for our assets Gas Emergencies If you smell gas or have accidentally hit the NTS pipeline please call us urgently 0800 111 999 Electricit...

Отзывы: