1.4 User Warnings.
Do not use the product for any purpose other than its intended use.
Use of the product in any way other than that outlined in 1.2 above is an infringement of the
intended purpose of this product and invalidates all guarantees.
Damages or losses resulting from improper use are excluded from coverage by the product
guarantee.
Do not remove or adjust any part of the product. Never attempt to work on or repair the
product yourself.
Risk of Scalding: During the operation of this product water temperatures within may reach
60°C.
If the buffer tank develops fault, switch off the source of heat and isolate all electrical supplies.
In all cases of fault contact the original installer or other competent person before contacting
Warmflow.
Frequent or routine topping up of the heating system to which this product is attached should
not be necessary and may prove harmful to the heating system including its fabric,
components, heating appliance(s) and this product. Should topping up prove necessary on a
frequent or routine basis you must contact your installer or Warmflow immediately. Where a
need for topping up applies, special consideration must be given to the concentration of
inhibitors within the heating system water and concentrations of inhibitor must be restored
without delay.
Documented records of the annual service of the heating system including this product must
be retained by the user.
BT
11
0
BT
200
DIMENSIONS
(A) Height (mm)
830
1380
(B) Flow Connections (mm)
530
1080
(C) Thermostat Pocket (mm)
530
868
(D) Return Connections
(mm)
257
257
OPERATING DATA
Maximum Operating Pressure (Bar)
3.0
3.0
Rated volume (litres)
107
194
Weight when full (kg)
140
240
Standing heat loss (kWh/24h)
1.43
1.78
FICHE DATA
Supplier Name
Warmflow
Supplier Model Identifier
BT110
BT200
Energy Efficiency Class
C
C
Standing Loss (W)
60
74
Storage Volume (litres)
107
194