3.6.3 Installation of Warmflow Optional Programmer (not applicable to the Kabin Pak
Combi)
1.
Disconnect the electrical supply.
2.
Remove top casing (4 studs) and control box cover (1 screw).
3.
Remove 2 screws securing blanking plate/programmer bracket. Remove bracket and
blanking plate from the control panel.
4.
Disconnect the blanking plate from bracket (2 screws).
5.
Feed programmer harness through the hole in the bracket. The programmer is secured
to the bracket with 2 screws.
6.
Disconnect the 6 pin plug from the CH and HW on/off plugs.
7.
Connect the programmer 6 pin plug into the socket.
8.
Locate the programmer into the hole in the facia and secure the bracket to the control
panel (2 screws).
9.
Set the time switch on the rear of the programmer to ‘G’ or ‘P’ (see programmer
instructions).
10.
Replace the control panel cover and reconnect electrical supply.
11.
Operational instructions are included in this handbook. (Section 11, Page 27)
CONTROL PANEL
BLANKING PLATE
OPITIONAL
PROGRAMMER
BLANKING PLATE/
PROGRAMMER
BRACKET
Page 21