6.3.2 Installation of Telescopic Low Level Conventional Flue
Installation instructions as per the balanced flue except there is only an inner seal, the
burner does not require modification and there is no flexible hose to be fitted. In addition
the low level flue should only protrude through the wall by a minimum of 155mm and a
maximum of 225mm.
6.3.3 Installation of Standard Low Level Flue (LLF)
After cutting a hole in the wall place the flue in the hole. The flue must be a minimum of
155mm through the wall. Fit the steel elbow into the pressed ring on the boiler and the
end of the flue kit. The elbow should then be sealed into both rings using high
temperature silicone sealant or fire cement which may also be used in conjunction
with glass fibre rope.
6.3.4 Installation of High Level Balanced Flue (HLBF)
Installation instructions as per the balanced flue except there are no seals involved as
the flue is not telescopic. There are no extension pieces available for these units.
Note
: When filling a HLBF to a Combi a new top panel with a larger cut out for the flue
is required.