9.6
Fitting a Standard Kabin Pak Vertical Flue Adaptor
1.
Remove the 2 screws connecting the flue main body to the Kabin Pak and lift off. It
may be necessary to break the seal between the flue main body and the top of the flue
pipe.
2.
Ensure that the gap between the existing flue pipe and top of the Kabin Pak is properly
sealed with high temperature silicone sealant.
3.
Once the flue main body has been removed fit the Kabin Pak adaptor (KPA) into
position and secure with the 2 screws. A 5” conventional flue can now be attached.
9.7
Slimline Kabin Pak
TOP PANEL REMOVABLE
FOR SERVICING
MOUNTING BRACKET
FOR DOUBLE
ELECTRICAL SOCKET
GROMMETS FOR OIL
AND ELECTRICAL
CABLE IF REQUIRED
LOCKABLE
FRONT PANEL
REAR PANEL
REMOVABLE
FOR ACCESS
GROMMETS IN
SIDE PANELS
FOR PIPEWORK
CUTOUTS IN
BASE FOR
PIPEWORK
FLUE
ELBOW
FLUE TERMINAL
COMPLETE WITH INTEGRAL
PROTECTIVE GUARD
Page 30