44
6.
INSTRUCTIONS FOR USE
6.1. Start
-
up
Fill tank with clean fuel. Only use Diesel or
Kerosene.
The fuel gauge on top of the tank allows to check
fuel level
Connect the power cord plug to a AC220V
-
240V 50
Hz earthed electrical supply system.
Earthing is mandatory.
For
i
ndirect fired heaters: connect the heater to a chimney or to an
exhaust duct. To get a proper draught in the chimney the exhaust gas path
must rise. Avoid any elbows and bends in the first part of the exhaust ducts
for at least 3 m.
When complete “start
-
up” above, the left display window shows “
--
”, the right display
window shows ambient temperature value.
Push the power switch to “on” position.
The default temperature setting is 20
℃
, be showed on the left display window.
If the ambient temperature is lower than default temperature, after waiting for 12
seconds per
-
ventilation, the heater starts.
If the ambient temperature is higher than default temperature, turn thermostat
control knob to desired temperature, after waiting for 7 seconds pre
-
ventilation, the
heater starts.
ABNORMAL OPERATION:
in case of malfunction (flame failure, reduced air flow,
bad combustion, etc.) the heater stops, the LOCK
-
OUT MODE code will be showed
on the display window
-
see troubleshooting.