Remove the ash drawer (see the previous page) and loosen the two 5/32’’ allen head screws shown
as D in the drawing below. Rotate the covers over the access holes and use a brush and vacuum to
clean the ash. Rotate the covers back over the holes and tighten the screws. Front View Looking into
the Ash Drawer Cavity with the Ash Drawer Removed.
CLEANING THE CONVECTION BLOWER
To clean the convention blower, remove the right side door (see the following page). Disconnect the
stove power cord from the electrical outlet. Remove the two screws (A in the drawing to the right)
securing the blower to the blower duct. Slide the blower to the rear disengaging it from the blower
duct. A vacuum can be used to remove any dust accumulation on the blower’s blades or inside the
blower duct. Caution should be used not to damage the blower’s blades during cleaning. Note that
future models of the stove may be built so that the screws A may just need to be loosened rather than
removed to remove the blower. To reinstall the blower, slide the blower back into the retaining lip B
and reinstall screws A.
CLEANING THE VENT PIPE
Soot and Fly ash: Formation and Need for Removal
The products of combustion will contain small particles of fly ash will collect in the exhaust venting
system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during start up,
shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect
in the exhaust venting system. The exhaust venting system should be inspected at least once every
year to determine if cleaning is necessary. Sweep the pipe as needed.
A tee and the cleanout in the vent system attached to the stove’s flue collar will facilitate this cleaning.
Required Cleaning Schedule after Number of Bags Burned
Burn Pot=10 bags
Ash Drawer=50 bags
Flue Fan=100 bags
Blower=100 bags
Содержание 5411074136796
Страница 39: ...9 Sch ma lectronique...
Страница 50: ...De afstand tussen wand en kachel als deze in het huis is ge nstalleerd MM...
Страница 74: ...9 Elektronisch Plan...
Страница 85: ...Horizontal and Up through the eave The Distance between wall and stove when it is installed in the house MM...
Страница 103: ...Against any unauthorized modification of the appliance The parts can be replaced only recommended by manufacturer...
Страница 112: ...9 Electronic Plan...