8
7
6. Immerse approximately 3/4 of the length of the stainless steel portion in a
container of the sanitizing solution and run for two (2) minutes on High.
7. dO nOt rInSe after SanItIZIng IS COMpLete. Allow to air
dry before use.
nOte
dO nOt IMMerSe pLaStIC HOuSIng In WaSHIng
SOLutIOn, rInSe Water, Or SanItIZIng SOLutIOn.
preVent LIQuId frOM runnIng IntO pLaStIC HOuSIng
BY WrIngIng aLL eXCeSS MOISture frOM CLOtHS Or
SpOngeS BefOre uSIng tHeM.
WarrantY –
LIMIted One Year WarrantY
Waring warrants every new WARING
®
COMMERCIAL PRODUCT to be
free from defects in material and workmanship for a period of 1 year from the
date of purchase when used with foodstuffs, nonabrasive liquids (other than
detergents) and nonabrasive semi-liquids, proving it has not been subjected to
loads in excess of the indicated rating.
Under this warranty, Waring
®
Commercial will repair or replace any part which,
upon examination, appears to us to be defective in materials or workmanship, pro-
vided the unit is delivered prepaid to the Waring Service Center at 314 Ella T.
Grasso Avenue, Torrington, CT 06790, or any Authorized Service Center.
This warranty does not: a) apply to any unit which has become worn, defective,
damaged or broken due to misuse, repairs, or servicing by other than the Waring
Service Center or an Authorized Service Center or due to abuse, misuse, over-
loading or tampering; b) cover consequential damages of any kind.
This warranty gives you specific legal rights, and you may have other rights
which vary from state to state so that certain limitations or exclusions set forth
above may not apply to you.
WARNING - This warranty is VOID if the appliance is used on Direct
Current (D.C.)
SerVICe
Refer to the list of Authorized Service Centers enclosed with your Waring
®
Commercial Product for the name of the nearest Service Center, or Contact
Waring in one of the following 3 ways:
1) Mail:
WARING Service Center,
314 Ella T. Grasso Ave.
Torrington, CT 06790 USA
2) Phone Product Service:
(800) 4WARING OR (800) 492-7464
3) Internet: http://www.waringproducts.com
E-mail: [email protected]
Ship units for repair to the above address or to an
Authorized Service Center. Do not ship to a Waring
Sales Office.
CLeanIng InStruCtIOnS
tHe QuIK StIK
®
IMMerSIOn BLender MuSt Be
CLeaned and drIed aCCOrdIng tO tHe fOLLOWIng
InStruCtIOnS after eaCH uSe.
for food Service applications
• Wash, rinse, and sanitize the stainless steel portion of the Quik Stik
®
prior
to initial use, after each use, or whenever it will not be used again within a
period of 1 hour.
• Clean and sanitize the plastic motor housing prior to initial use and after
each use.
• Washing solutions based on non-sudsing detergents, and chlorine-based
sanitizing solutions having a minimum chloride concentration of 100 PPM
are recommended.
The following washing, rinsing, and sanitizing solutions, or their equivalents,
may be used.
dILutIOn
SOLutIOn prOduCt
In Water teMperature
Washing
Diversey Wyandotte 4 Tbls./Gallon Hot 115°F (46°C)
Diversol BX/A
Or CX/A
Rinsing
Plain Water
Warm 95°F (35°C)
Sanitizing
Clorox Institutional 1 Tbl./Gallon Cold 50-70°F (10°-21°C)
Bleach
• In repetitive use applications, frequent cleaning will prolong life.
to wash and sanitize the Quik Stik
®
:
1. Rinse the exterior and interior stainless steel portion of the Quik Stik
®
under running water. Scrub and flush the exterior and interior stainless
steel portion to dislodge and remove as much food residue as possible.
2. Wipe down the exterior of the plastic housing and the stainless steel
portion of the Quik Stik
®
with a soft cloth or sponge dampened with
the washing solution.
3. Immerse approximately 3/4 of the length of the stainless steel portion in
a container of the washing solution and run for two (2) minutes on High.
4. Repeat steps two (2) and three (3) using clean rinse water in place of the
washing solution.
nOte - IMpOrtant
In Order tO MInIMIZe tHe pOSSIBILItY Of SCaLdIng,
teMperature Of tHe WaSHIng SOLutIOn and rInSe
Water MuSt nOt eXCeed 115°f (46°C).
5. Wipe down the exterior of the plastic housing and the stainless steel
portion of the Quik Stik
®
with a soft cloth or sponge dampened with
the sanitizing solution.
Waring Commercial
314 Ella T. Grasso Ave.
Torrington, CT 06790
03WA23244
IB-3971B