Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-14
9.5.4
Stainless steel cardan joint KL 30
– KL 100
Dismounting:
1.
Remove rotor.
2.
Undo and remove both screws 1957 of a side of the joint with a screwdriver / Allen wrench.
Push out connecting bolt 1959.
3.
Remove joint 2094.
4.
Undo and remove both screws 1957 of the drive side of the joint. Push out
connecting bolt 1959.
5.
Check connecting parts 2094 and middle part 1387 if damaged change them.
Mounting:
1.
Mount pump in reverse order.
Always renew the O-rings that have been removed.
(O-ring 1962 and O-ring 2088).
Fig. 9-13