80
W&T
Packetizing serial datagrams
10�1
Packet Options
Packet Options in the menu path
Setup Port x
r
TCP/IP Mode
r
SystemOptions
are criteria which allow the Com-Server to
detect the start and end of contiguous datagrams in serial
receiving. They allow a serial datagram to be sent to the
communication partner closed in a network packet. Such data-
gram-optimized transmission is often necessary in tunneling
and transmission of serial protocols which require synchro-
nous reception of the data packets with a defined character
delay time.
For serial protocols which emphasize the greatest possible
latency-free transmission and shortest possible acknow-
ledgement delay time, Packet Options should not be used.
By factory default the Com-Server operates latency-optimized
and sends received data as soon as possible to the respective
communication partner.
1
Regardless of how Packet Options is configured, the
Com-Server sends all received data to the network-side
communication partner as soon as the set MTU is reached.
The factory default setting for this is 560 bytes. In the menu
path
Setup System
r
Setup TCP/IP
r
MTU
this can be in-
creased to max. 1024 bytes.
The set Packet Options apply to the following Com-Server
modes.
• TCP client
• TCP server
• UDP peer
• COM redirector
• Box-to-Box
• OPC server
Содержание Com-Server++
Страница 8: ...W T...
Страница 26: ...26 W T Assigning the IP address...
Страница 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Страница 30: ...30 W T Supply voltage...
Страница 34: ...34 W T Network interface...
Страница 35: ...35 W T Subject to error and alteration 5 The serial combi port Mode selection RS232 mode RS422 485 mode...
Страница 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Страница 88: ...88 W T Packetizing serial datagrams...
Страница 94: ...94 W T Mode TCP server...
Страница 108: ...108 W T Mode TCP client...
Страница 122: ...122 W T UDP bus mode...
Страница 130: ...130 W T The Windows COM port redirector...
Страница 138: ...138 W T Box to Box mode...
Страница 154: ...154 W T Mode FTP client...
Страница 164: ...164 W T Mode Telnet Client...
Страница 182: ...182 W T OPC data transfer...
Страница 183: ...183 W T Subject to error and alteration 23 Mode InQueueCopy Distribution of serial data streams to multiple stations...
Страница 186: ...186 W T Mode InQueueCopy...
Страница 206: ...206 W T Expanded services of the Com Server...