![W&T Com-Server++ Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/wandt/com-server/com-server_manual_3083827113.webp)
113
W&T
Mode UDP peer
Subject to error and alteration
13�1�3 UDP client mode serial addressing
SETUP Port x
TCP/IP Mode
...
UDP Client
...
Special Options
Client: "C"+Addr
Disconnect Char
In this node the address data of the destination system are
not permanently configured, but rather sent serially to the
Com-Server as an ASCII string before the actual user data.
This makes it possible to make connections to changing UDP
servers.
n
Client: „C“+Addr
Default: deactive
Activating this switch activates UDP client mode to alter-
nating UDP peers. The address of the UDP peer need not
be permanently configured, rather it is send as an ASCII
string in front on the user data on the serial port. The
string for addressing is not included in the send. There are
two possibilities for string format:
1. The parameters
Server Port
and
Server IP/URL
are
zero.
C
[IP address or URL
]
,[port number
]<CR>
Example:
C172.16.231.101,4800<CR>
Cwww.comserver.com,9100<CR>
2.
The parameter
Server Port
contains the Default Port
(e.g. 4800),
Server IP/URL
contains the first three bytes of
the IP address (e.g.172.16.231.0).
C
4.Byte IP address
<CR>
(e.g. „C101<CR>“)
1
A URL can only be assigned in conjunction with a
valid DNS server. The name used is not allowed to
contain space characters (0x20), nor can the first cha-
racter be a decimal (0x2E). A server IP or URL is deleted
Содержание Com-Server++
Страница 8: ...W T...
Страница 26: ...26 W T Assigning the IP address...
Страница 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Страница 30: ...30 W T Supply voltage...
Страница 34: ...34 W T Network interface...
Страница 35: ...35 W T Subject to error and alteration 5 The serial combi port Mode selection RS232 mode RS422 485 mode...
Страница 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Страница 88: ...88 W T Packetizing serial datagrams...
Страница 94: ...94 W T Mode TCP server...
Страница 108: ...108 W T Mode TCP client...
Страница 122: ...122 W T UDP bus mode...
Страница 130: ...130 W T The Windows COM port redirector...
Страница 138: ...138 W T Box to Box mode...
Страница 154: ...154 W T Mode FTP client...
Страница 164: ...164 W T Mode Telnet Client...
Страница 182: ...182 W T OPC data transfer...
Страница 183: ...183 W T Subject to error and alteration 23 Mode InQueueCopy Distribution of serial data streams to multiple stations...
Страница 186: ...186 W T Mode InQueueCopy...
Страница 206: ...206 W T Expanded services of the Com Server...