W&T 81215 Скачать руководство пользователя страница 5

17

Subject to error and alteration

W&T

 

 

Universal Fiber Optic Interface Converter

Universal FO Interface  RS232/RS422/RS485, #81215

Function

The W&T fiber optic interface converter 81215 allows  
bi-directional conversion of an RS232, RS422 or RS485  
interface into a fiber optic interface with a transmission speed 
of up to 500.000 bps. 

The interface works independently of the data format used 
and converts one data line in each direction.

Well-known SC connectors are used for connecting the glass 
fiber optic cable, whereas the serial interface is configured as 
a 9-pin SUB-D connector. 

Power Supply

The supply voltage for the Interfaces is provided through an 
integrated switching regulator. This regulator has a variable 
input voltage range and allows the Interface to be powered by 
any DC voltage between 12 and 48 volts.

The supply voltage is polarity reversal protected and can be 
connected on the underside of the Interface through the inclu-
ded plug-in screw terminal.

Galvanic isolation and ESD protection

The serial port of the fiber optic converter is galvanically  
isolated from the supply voltage through a DC/DC converter 
with an isolation voltage of 1kV. All signal lines for the serial 
interface are protected by ESD-immune interface chips against 
static discharge for voltages up to 15 kV corresponding to IEC 
801-2, Level 4. 

Содержание 81215

Страница 1: ...13 Subject to error and alteration W T Universal Fiber Optic Interface Converter Manual Universal FO Interface Converter Model 81215 Release 1 0 W T...

Страница 2: ...rification Please inform us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T products only to the extent that...

Страница 3: ...fiber optic solution offers another significant advanta ge The data transfer is carried out with minimal delay and enables the processing of real time protocols Wiesemann Theis offers an entire famil...

Страница 4: ...ply 17 Galvanic isolation and ESD protection 17 Display elements 18 Serial Port 19 RS232 mode 19 RS422 mode 19 RS485 mode 19 RS422 RS485 4 wire bus master application 19 RS485 4 wire RS485 2 wire appl...

Страница 5: ...SUB D connector Power Supply The supply voltage for the Interfaces is provided through an integrated switching regulator This regulator has a variable input voltage range and allows the Interface to b...

Страница 6: ...the fiber optic converter is configu red as a DB9 plug The pin configuration can be seen in the following table Pin RS232 signal RS422 RS485 signal 1 n c TxD A 2 RxD RxD A 3 TxD DTR A active level 4...

Страница 7: ...TxD in both directions RS422 mode This mode provides one data channel each RxD and TxD in both directions The RS422 sender and receiver chips are always active RS485 mode In all RS485 modes there is a...

Страница 8: ...ain after the end of transmission The RS485 receiving channel is deactivated when the driver is on but is switched on when the driver is in the high impedance state Please see the following table for...

Страница 9: ...310 nm Depending on the attenuation value of the glass fiber optic cable used data transmission over a distance of up to 20 km is possible using the Interface in its standard version A special version...

Страница 10: ...as article number 81900 Housing The W T Fiber Optic Interface is contained in a plastic housing for mounting on standard rails according to DIN EN 50022 35 To configure the RS232 RS422 RS485 Interfac...

Страница 11: ...T plug adapter on request Fiber optic medium Duplex single mode fiber 9 125 m Duplex multi mode fiber 50 125 m or 62 5 125 m Wavelength 1310 nm Output power Single mode fiber min 12dBm max 8dBm Class...

Страница 12: ...5 08mm spacing labeled L and M Galvanically isolation min 1 kV between serial interface and power supply Misc Ambient temperature Storage 40 70 C Operation 0 70 C Permissible relative humidity 0 95 rH...